    An In Vitro Experimental Study of the Pulse Delivery Method in Irreversible Electroporation

    Source: Journal of Engineering and Science in Medical Diagnostics and Therapy:;2019:;volume( 001 ):;issue: 001::page 14501
    Author:
    Zhang, Bing
    ,
    Moser, Michael A. J.
    ,
    Zhang, Edwin M.
    ,
    Xiang, Jim
    ,
    Zhang, Wenjun
    DOI: 10.1115/1.4038238
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The purpose of this study was to investigate the feasibility of generating larger ablation volumes using the pulse delivery method in irreversible electroporation (IRE) using a potato model. Ten types of pulse timing schemes and two pulse repetition rates (1 pulse per 200 ms and 1 pulse per 550 ms) were proposed in the study. Twenty in vitro experiments with five samples each were performed to check the effects on the ablation volumes for the ten pulse timing schemes and two pulse repetition rates. At the two pulse repetition rates (1 pulse per 200 ms and 1 pulse per 550 ms), the largest ablation volumes achieved were 1634.1 mm3± 122.6 and 1828.4 mm3±160.9, respectively. Compared with the baseline approach (no pulse delays), the ablation volume was increased approximately by 62.8% and 22.6% at the repetition rates of 1 pulse per 200 ms and 1 pulse per 550 ms, respectively, using the pulse timing approach (with pulse delays). With the pulse timing approach, the ablation volumes generated at the lower pulse repetition rate were significantly larger than those generated at the higher pulse repetition rate (P < 0.001). For the experiments with one pulse train (baseline approach), the current was 5.2 A±0.4. For the experiments with two pulse trains, the currents were 6.4 A±0.9 and 6.8 A±0.9, respectively (P = 0.191). For the experiments with three pulse trains, the currents were 6.6 A±0.6, 6.9 A±0.6, and 6.5 A±0.6, respectively (P = 0.216). For the experiments with five pulse trains, the currents were 6.6 A±0.9, 6.9 A±0.9, 6.5 A±1.0, 6.5 A±1.0, and 5.7 A±1.2, respectively (P = 0.09). This study concluded that: (1) compared with the baseline approach used clinically, the pulse timing approach is able to increase the volume of ablation; but, the pulse timing scheme with the best performance might be various with the tissue type; (2) the pulse timing approach is still effective in achieving larger ablation volumes when the pulse repetition rate changes; but, the best pulse timing scheme might be different with the pulse repletion rate; (3) the current in the base line approach was significantly smaller than that in the pulse timing approach.
    • Download: (1.502Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      An In Vitro Experimental Study of the Pulse Delivery Method in Irreversible Electroporation

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4256012
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    Show full item record

    contributor authorZhang, Bing
    contributor authorMoser, Michael A. J.
    contributor authorZhang, Edwin M.
    contributor authorXiang, Jim
    contributor authorZhang, Wenjun
    date accessioned2019-03-17T10:13:57Z
    date available2019-03-17T10:13:57Z
    date copyright11/7/2017 12:00:00 AM
    date issued2019
    identifier issn2572-7958
    identifier otherjesmdt_001_01_014501.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4256012
    description abstractThe purpose of this study was to investigate the feasibility of generating larger ablation volumes using the pulse delivery method in irreversible electroporation (IRE) using a potato model. Ten types of pulse timing schemes and two pulse repetition rates (1 pulse per 200 ms and 1 pulse per 550 ms) were proposed in the study. Twenty in vitro experiments with five samples each were performed to check the effects on the ablation volumes for the ten pulse timing schemes and two pulse repetition rates. At the two pulse repetition rates (1 pulse per 200 ms and 1 pulse per 550 ms), the largest ablation volumes achieved were 1634.1 mm3± 122.6 and 1828.4 mm3±160.9, respectively. Compared with the baseline approach (no pulse delays), the ablation volume was increased approximately by 62.8% and 22.6% at the repetition rates of 1 pulse per 200 ms and 1 pulse per 550 ms, respectively, using the pulse timing approach (with pulse delays). With the pulse timing approach, the ablation volumes generated at the lower pulse repetition rate were significantly larger than those generated at the higher pulse repetition rate (P < 0.001). For the experiments with one pulse train (baseline approach), the current was 5.2 A±0.4. For the experiments with two pulse trains, the currents were 6.4 A±0.9 and 6.8 A±0.9, respectively (P = 0.191). For the experiments with three pulse trains, the currents were 6.6 A±0.6, 6.9 A±0.6, and 6.5 A±0.6, respectively (P = 0.216). For the experiments with five pulse trains, the currents were 6.6 A±0.9, 6.9 A±0.9, 6.5 A±1.0, 6.5 A±1.0, and 5.7 A±1.2, respectively (P = 0.09). This study concluded that: (1) compared with the baseline approach used clinically, the pulse timing approach is able to increase the volume of ablation; but, the pulse timing scheme with the best performance might be various with the tissue type; (2) the pulse timing approach is still effective in achieving larger ablation volumes when the pulse repetition rate changes; but, the best pulse timing scheme might be different with the pulse repletion rate; (3) the current in the base line approach was significantly smaller than that in the pulse timing approach.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAn In Vitro Experimental Study of the Pulse Delivery Method in Irreversible Electroporation
    typeJournal Paper
    journal volume1
    journal issue1
    journal titleJournal of Engineering and Science in Medical Diagnostics and Therapy
    identifier doi10.1115/1.4038238
    journal fristpage14501
    journal lastpage014501-6
    treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2019:;volume( 001 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian