    Performance Evaluation of Combined Photovoltaic Thermal Water Cooling System for Hot Climate Regions

    Source: Journal of Solar Energy Engineering:;2019:;volume( 141 ):;issue: 004::page 41010
    Author:
    Salem Ahmed, M.
    ,
    Mohamed, A. S. A.
    ,
    Maghrabie, Hussein M.
    DOI: 10.1115/1.4042723
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Solar electric power generation utilizing photovoltaic (PV) modules is associated with low electrical efficiency that substantially decreases as its surface temperature exceeds an appropriate limit, particularly in hot climate regions. Consequently, it is required to keep PV modules relatively under a condition of low temperature using a cooling system as possible. The present experimental study evaluates the performance of the combined photovoltaic thermal (PV/T) module employing a water cooling system attached to the back surface during June for the city of Sohag in Egypt. The experimental results show that utilizing a water cooling system decreases the average surface temperature of the PV module from 44.8 °C to 30.3 °C on the back side and from 46.6 °C to 36.9 °C on the front side. The maximum value of the thermal heat gain of the PV/T module that is maintained at noon equals 230 W, and the corresponding value of the electrical power output is 34.4 W. Furthermore, the electrical efficiency of the PV/T module is 8% higher than that of the PV module without a water cooling system. Finally, the maximum and average values of the overall efficiency of PV/T module are 76.4% and 68.9%, respectively.
    • Download: (2.086Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Performance Evaluation of Combined Photovoltaic Thermal Water Cooling System for Hot Climate Regions

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4255902
    Collections
    • Journal of Solar Energy Engineering

    Show full item record

    contributor authorSalem Ahmed, M.
    contributor authorMohamed, A. S. A.
    contributor authorMaghrabie, Hussein M.
    date accessioned2019-03-17T10:05:28Z
    date available2019-03-17T10:05:28Z
    date copyright2/19/2019 12:00:00 AM
    date issued2019
    identifier issn0199-6231
    identifier othersol_141_04_041010.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4255902
    description abstractSolar electric power generation utilizing photovoltaic (PV) modules is associated with low electrical efficiency that substantially decreases as its surface temperature exceeds an appropriate limit, particularly in hot climate regions. Consequently, it is required to keep PV modules relatively under a condition of low temperature using a cooling system as possible. The present experimental study evaluates the performance of the combined photovoltaic thermal (PV/T) module employing a water cooling system attached to the back surface during June for the city of Sohag in Egypt. The experimental results show that utilizing a water cooling system decreases the average surface temperature of the PV module from 44.8 °C to 30.3 °C on the back side and from 46.6 °C to 36.9 °C on the front side. The maximum value of the thermal heat gain of the PV/T module that is maintained at noon equals 230 W, and the corresponding value of the electrical power output is 34.4 W. Furthermore, the electrical efficiency of the PV/T module is 8% higher than that of the PV module without a water cooling system. Finally, the maximum and average values of the overall efficiency of PV/T module are 76.4% and 68.9%, respectively.
    publisherThe American Society of Mechanical Engineers (ASME)
    titlePerformance Evaluation of Combined Photovoltaic Thermal Water Cooling System for Hot Climate Regions
    typeJournal Paper
    journal volume141
    journal issue4
    journal titleJournal of Solar Energy Engineering
    identifier doi10.1115/1.4042723
    journal fristpage41010
    journal lastpage041010-10
    treeJournal of Solar Energy Engineering:;2019:;volume( 141 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian