    A Micromachined Pb(Mg1/3Nb2/3)O3-PbTiO3 Single Crystal Composite Circular Array for Intravascular Ultrasound Imaging

    Source: Journal of Engineering and Science in Medical Diagnostics and Therapy:;2019:;volume( 002 ):;issue: 002::page 21001
    Author:
    Li, Sibo
    ,
    Tian, Jian
    ,
    Jiang, Xiaoning
    DOI: 10.1115/1.4041443
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper describes the design, fabrication, and characterization of a micromachined high-frequency Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) single crystal/epoxy 1–3 composite ultrasound circular array. The 1–3 composites were fabricated by deep reactive ion etching (DRIE) of PMN-PT single crystal. The feature size of single crystal pillars was 18 μm in diameter. The kerf between pillars was less than 4 μm. A 50-element circular array transducer (radially outward) with the pitch of 100 μm was wrapped around a needle resulting in an outer diameter of 1.7 mm. The array test showed that the center frequency reached 39±2 MHz and −6-dB fractional bandwidth was 82±6%. The insertion loss was −41 dB, and crosstalk between adjacent elements was −24 dB. A radial outward imaging testing with phantom wires (D = 50 μm) was conducted. The image was in a dynamic range of 30 dB to show a penetration depth of 6 mm by using the synthetic aperture method. The −6-dB beam width was estimated to be 60 μm in the axial direction at 3.1 mm distance away from the probe. The results suggest that the 40 MHz micromachined 1–3 composite circular array is promising for intravascular ultrasound (IVUS) imaging applications.
    • Download: (2.332Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Micromachined Pb(Mg1/3Nb2/3)O3-PbTiO3 Single Crystal Composite Circular Array for Intravascular Ultrasound Imaging

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4255536
    Collections
    • Journal of Engineering and Science in Medical Diagnostics and Therapy

    Show full item record

    contributor authorLi, Sibo
    contributor authorTian, Jian
    contributor authorJiang, Xiaoning
    date accessioned2019-03-17T09:31:55Z
    date available2019-03-17T09:31:55Z
    date copyright1/18/2019 12:00:00 AM
    date issued2019
    identifier issn2572-7958
    identifier otherjesmdt_002_02_021001.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4255536
    description abstractThis paper describes the design, fabrication, and characterization of a micromachined high-frequency Pb(Mg1/3Nb2/3)O3-PbTiO3 (PMN-PT) single crystal/epoxy 1–3 composite ultrasound circular array. The 1–3 composites were fabricated by deep reactive ion etching (DRIE) of PMN-PT single crystal. The feature size of single crystal pillars was 18 μm in diameter. The kerf between pillars was less than 4 μm. A 50-element circular array transducer (radially outward) with the pitch of 100 μm was wrapped around a needle resulting in an outer diameter of 1.7 mm. The array test showed that the center frequency reached 39±2 MHz and −6-dB fractional bandwidth was 82±6%. The insertion loss was −41 dB, and crosstalk between adjacent elements was −24 dB. A radial outward imaging testing with phantom wires (D = 50 μm) was conducted. The image was in a dynamic range of 30 dB to show a penetration depth of 6 mm by using the synthetic aperture method. The −6-dB beam width was estimated to be 60 μm in the axial direction at 3.1 mm distance away from the probe. The results suggest that the 40 MHz micromachined 1–3 composite circular array is promising for intravascular ultrasound (IVUS) imaging applications.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Micromachined Pb(Mg1/3Nb2/3)O3-PbTiO3 Single Crystal Composite Circular Array for Intravascular Ultrasound Imaging
    typeJournal Paper
    journal volume2
    journal issue2
    journal titleJournal of Engineering and Science in Medical Diagnostics and Therapy
    identifier doi10.1115/1.4041443
    journal fristpage21001
    journal lastpage021001-8
    treeJournal of Engineering and Science in Medical Diagnostics and Therapy:;2019:;volume( 002 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian