    Validated Simulations of Heat Transfer From a Vertical Heated-Rod Array to a Helium-Filled Isothermal Enclosure

    Source: Journal of Thermal Science and Engineering Applications:;2018:;volume( 010 ):;issue: 002::page 21007
    Author:
    Maharjan, Dilesh
    ,
    Hadj-Nacer, Mustafa
    ,
    Chalasani, Narayana
    ,
    Greiner, Miles
    DOI: 10.1115/1.4037493
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Measurements of heat transfer from an array of vertical heater rods to the walls of a square, helium-filled enclosure are performed for a range of enclosure temperatures, helium pressures, and rod heat generation rates. This configuration is relevant to a used nuclear fuel assembly within a dry storage canister. The measurements are used to assess the accuracy of computational fluid dynamics (CFD)/radiation simulations in the same configuration. The simulations employ the measured enclosure temperatures as boundary conditions and predict the temperature difference between the rods and enclosure. These temperature differences are as large as 72 °C for some experiments. The measured temperature of rods near the periphery of the array is sensitive to small, uncontrolled variations in their location. As a result, those temperatures are not as useful for validating the simulations as measurements from rods near the array center. The simulated rod temperatures exhibit random differences from the measurements that are as large as 5.7 °C, but the systematic (average) error is 1 °C or less. The random difference between the simulated and measured maximum array temperature is 2.1 °C, which is less than 3% of the maximum rod-to-wall temperature difference.
    • Download: (3.014Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Validated Simulations of Heat Transfer From a Vertical Heated-Rod Array to a Helium-Filled Isothermal Enclosure

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4253030
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorMaharjan, Dilesh
    contributor authorHadj-Nacer, Mustafa
    contributor authorChalasani, Narayana
    contributor authorGreiner, Miles
    date accessioned2019-02-28T11:08:00Z
    date available2019-02-28T11:08:00Z
    date copyright9/6/2017 12:00:00 AM
    date issued2018
    identifier issn1948-5085
    identifier othertsea_010_02_021007.pdf
    identifier urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4253030
    description abstractMeasurements of heat transfer from an array of vertical heater rods to the walls of a square, helium-filled enclosure are performed for a range of enclosure temperatures, helium pressures, and rod heat generation rates. This configuration is relevant to a used nuclear fuel assembly within a dry storage canister. The measurements are used to assess the accuracy of computational fluid dynamics (CFD)/radiation simulations in the same configuration. The simulations employ the measured enclosure temperatures as boundary conditions and predict the temperature difference between the rods and enclosure. These temperature differences are as large as 72 °C for some experiments. The measured temperature of rods near the periphery of the array is sensitive to small, uncontrolled variations in their location. As a result, those temperatures are not as useful for validating the simulations as measurements from rods near the array center. The simulated rod temperatures exhibit random differences from the measurements that are as large as 5.7 °C, but the systematic (average) error is 1 °C or less. The random difference between the simulated and measured maximum array temperature is 2.1 °C, which is less than 3% of the maximum rod-to-wall temperature difference.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleValidated Simulations of Heat Transfer From a Vertical Heated-Rod Array to a Helium-Filled Isothermal Enclosure
    typeJournal Paper
    journal volume10
    journal issue2
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4037493
    journal fristpage21007
    journal lastpage021007-9
    treeJournal of Thermal Science and Engineering Applications:;2018:;volume( 010 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian