Quantitative Assessment of Phase Change Material Utilization for Building Cooling Load Abatement in Composite Climatic ConditionSource: Journal of Solar Energy Engineering:;2018:;volume( 140 ):;issue: 001::page 11001DOI: 10.1115/1.4038047Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: The global trend of energy consumption shows that buildings consume around 48% of the total energy, of which, over 50% is for heating and cooling applications. This study elucidates on cooling load reduction with phase change material (PCM) incorporation in a building envelope. PCM provides thermal shielding due to isothermal heat storage during phase change. PCM selection depends upon its phase change temperature, thermal capacity, and thermal conductivity, as they play a vital role in assessing their impact on energy conservation in buildings. The uniqueness of this study underlies in the fact that it focuses on the utilization of PCM for New Delhi (28.54°N, 77.19°E) climatic conditions and adjudges the suitability of three commercially available PCMs, based on the overall heat load reduction and their characteristic charging/discharging. The study aims at finding an optimum melting and solidification temperature of the PCM such that it may be discharged during the night by releasing the heat gained during the day and mark its suitability. The results of mathematical modeling indicate that as per the design conditions, the melting/solidification temperature of 34 °C is suitable for New Delhi to absorb the peak intensity of solar irradiation during summer. Based on the thermophysical properties in literature (Pluss Advanced Technologies Pvt. Ltd., 2015, “Technical Data Sheet of savE® HS29, PLUSS-TDS-DOC-304 Version R0,” Pluss Advanced Technologies Pvt. Ltd., Gurgaon, India. Pluss Advanced Technologies Pvt. Ltd., 2015, “Technical Data Sheet of savE® OM32, PLUSS-TDS-DOC-394 Version R0,” Pluss Advanced Technologies Pvt. Ltd., Gurgaon, India. Pluss Advanced Technologies Pvt. Ltd., 2012, “Technical Data Sheet - savEVR HS34, Doc:305,” Pluss Advanced Technologies Pvt. Ltd., Gurgaon, India), mathematical modeling showed HS34 to be suitable for New Delhi among the three PCMs. To ratify this, characteristic charging and discharging of HS34 is tested experimentally, using differential scanning calorimeter (DSC). The results showed that HS34 is a heterogeneous mixture of hydrated salts having super-cooling of 6 °C, reducing its peak solidification temperature to 30.52 °C during the cooling cycle also making it unsuitable for peak summers in New Delhi.
|
Collections
Show full item record
contributor author | Saxena, Rajat | |
contributor author | Biplab, Kumar | |
contributor author | Rakshit, Dibakar | |
date accessioned | 2019-02-28T11:07:28Z | |
date available | 2019-02-28T11:07:28Z | |
date copyright | 10/17/2017 12:00:00 AM | |
date issued | 2018 | |
identifier issn | 0199-6231 | |
identifier other | sol_140_01_011001.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl1/handle/yetl/4252938 | |
description abstract | The global trend of energy consumption shows that buildings consume around 48% of the total energy, of which, over 50% is for heating and cooling applications. This study elucidates on cooling load reduction with phase change material (PCM) incorporation in a building envelope. PCM provides thermal shielding due to isothermal heat storage during phase change. PCM selection depends upon its phase change temperature, thermal capacity, and thermal conductivity, as they play a vital role in assessing their impact on energy conservation in buildings. The uniqueness of this study underlies in the fact that it focuses on the utilization of PCM for New Delhi (28.54°N, 77.19°E) climatic conditions and adjudges the suitability of three commercially available PCMs, based on the overall heat load reduction and their characteristic charging/discharging. The study aims at finding an optimum melting and solidification temperature of the PCM such that it may be discharged during the night by releasing the heat gained during the day and mark its suitability. The results of mathematical modeling indicate that as per the design conditions, the melting/solidification temperature of 34 °C is suitable for New Delhi to absorb the peak intensity of solar irradiation during summer. Based on the thermophysical properties in literature (Pluss Advanced Technologies Pvt. Ltd., 2015, “Technical Data Sheet of savE® HS29, PLUSS-TDS-DOC-304 Version R0,” Pluss Advanced Technologies Pvt. Ltd., Gurgaon, India. Pluss Advanced Technologies Pvt. Ltd., 2015, “Technical Data Sheet of savE® OM32, PLUSS-TDS-DOC-394 Version R0,” Pluss Advanced Technologies Pvt. Ltd., Gurgaon, India. Pluss Advanced Technologies Pvt. Ltd., 2012, “Technical Data Sheet - savEVR HS34, Doc:305,” Pluss Advanced Technologies Pvt. Ltd., Gurgaon, India), mathematical modeling showed HS34 to be suitable for New Delhi among the three PCMs. To ratify this, characteristic charging and discharging of HS34 is tested experimentally, using differential scanning calorimeter (DSC). The results showed that HS34 is a heterogeneous mixture of hydrated salts having super-cooling of 6 °C, reducing its peak solidification temperature to 30.52 °C during the cooling cycle also making it unsuitable for peak summers in New Delhi. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Quantitative Assessment of Phase Change Material Utilization for Building Cooling Load Abatement in Composite Climatic Condition | |
type | Journal Paper | |
journal volume | 140 | |
journal issue | 1 | |
journal title | Journal of Solar Energy Engineering | |
identifier doi | 10.1115/1.4038047 | |
journal fristpage | 11001 | |
journal lastpage | 011001-15 | |
tree | Journal of Solar Energy Engineering:;2018:;volume( 140 ):;issue: 001 | |
contenttype | Fulltext |