YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Development and Validation of a Brain Phantom for Therapeutic Cooling Devices

    Source: Journal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 005::page 51007
    Author:
    Packett, Ryan D. M.
    ,
    Brown, Philip J.
    ,
    Popli, Gautam S. S.
    ,
    Scott Gayzik, F.
    DOI: 10.1115/1.4036215
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Tissue cooling has been proven as a viable therapy for multiple conditions and injuries and has been applied to the brain to treat epilepsy and concussions, leading to improved long-term outcomes. To facilitate the study of temperature reduction as a function of various cooling methods, a thermal brain phantom was developed and analyzed. The phantom is composed of a potassium-neutralized, superabsorbent copolymer hydrogel. The phantom was tested in a series of cooling trials using a cooling block and 37 deg water representing nondirectional blood flow ranging up to 6 gph, a physiologically representative range based on the prototype volume. Results were compared against a validated finite difference (FD) model. Two sets of parameters were used in the FD model: one set to represent the phantom itself and a second set to represent brain parenchyma. The model was then used to calculate steady-state cooling at a depth of 5 mm for all flow rates, for both the phantom and a model of the brain. This effort was undertaken to (1) validate the FD model against the phantom results and (2) evaluate how similar the thermal response of the phantom is to that of a perfused brain. The FD phantom model showed good agreement with the empirical phantom results. Furthermore, the empirical phantom agreed with the predicted brain response within 3.5% at physiological flow, suggesting a biofidelic thermal response. The phantom will be used as a platform for future studies of thermally mediated therapies applied to the cerebral cortex.
    • Download: (1.168Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Development and Validation of a Brain Phantom for Therapeutic Cooling Devices

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4235685
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorPackett, Ryan D. M.
    contributor authorBrown, Philip J.
    contributor authorPopli, Gautam S. S.
    contributor authorScott Gayzik, F.
    date accessioned2017-11-25T07:19:14Z
    date available2017-11-25T07:19:14Z
    date copyright2017/6/4
    date issued2017
    identifier issn0148-0731
    identifier otherbio_139_05_051007.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4235685
    description abstractTissue cooling has been proven as a viable therapy for multiple conditions and injuries and has been applied to the brain to treat epilepsy and concussions, leading to improved long-term outcomes. To facilitate the study of temperature reduction as a function of various cooling methods, a thermal brain phantom was developed and analyzed. The phantom is composed of a potassium-neutralized, superabsorbent copolymer hydrogel. The phantom was tested in a series of cooling trials using a cooling block and 37 deg water representing nondirectional blood flow ranging up to 6 gph, a physiologically representative range based on the prototype volume. Results were compared against a validated finite difference (FD) model. Two sets of parameters were used in the FD model: one set to represent the phantom itself and a second set to represent brain parenchyma. The model was then used to calculate steady-state cooling at a depth of 5 mm for all flow rates, for both the phantom and a model of the brain. This effort was undertaken to (1) validate the FD model against the phantom results and (2) evaluate how similar the thermal response of the phantom is to that of a perfused brain. The FD phantom model showed good agreement with the empirical phantom results. Furthermore, the empirical phantom agreed with the predicted brain response within 3.5% at physiological flow, suggesting a biofidelic thermal response. The phantom will be used as a platform for future studies of thermally mediated therapies applied to the cerebral cortex.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDevelopment and Validation of a Brain Phantom for Therapeutic Cooling Devices
    typeJournal Paper
    journal volume139
    journal issue5
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4036215
    journal fristpage51007
    journal lastpage051007-7
    treeJournal of Biomechanical Engineering:;2017:;volume( 139 ):;issue: 005
    contenttypeFulltext