Show simple item record

contributor authorDeng, Q.
contributor authorBurke, R. D.
contributor authorZhang, Q.
contributor authorPohorelsky, Ludek
date accessioned2017-11-25T07:15:53Z
date available2017-11-25T07:15:53Z
date copyright2017/24/1
date issued2017
identifier issn0742-4795
identifier othergtp_139_06_062603.pdf
identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4233724
description abstractTurbochargers are key components of engine air-paths that must be carefully considered during the development process. The combination of fluid, mechanical, and thermal phenomenon make the turbocharger a highly dynamic and nonlinear modeling challenge. The aim of this study is to quantify the dynamic response of the turbocharger system across a frequency spectrum from 0.003 Hz to 500 Hz, i.e., for exhaust gas pulsation in steady state, load steps, and cold start drive cycles, to validate the assumption of quasi-steady assumptions for particular modeling problems. A waste-gated turbine was modeled using the dual orifice approach, a lumped capacitance heat transfer model, and novel, physics-based pneumatic actuator mechanism model. Each submodel has been validated individually against the experimental measurements. The turbine inlet pressure and temperature and the waste-gate actuator pressure were perturbed across the full frequency range both individually and simultaneously in separate numerical investigations. The dynamic responses of turbine housing temperature, turbocharger rotor speed, waste-gate opening, mass flow, and gas temperatures/pressures were all investigated. The mass flow parameter exhibits significant dynamic behavior above 100 Hz, illustrating that the quasi-steady assumption is invalid in this frequency range. The waste-gate actuator system showed quasi-steady behavior below 10 Hz, while the mechanical inertia of the turbine attenuated fluctuations in shaft speed for frequencies between 0.1 and 10 Hz. The thermal inertia of the turbocharger housing meant that housing temperature variations were supressed at frequencies above 0.01 Hz. The results have been used to illustrate the importance of model parameters for three transient simulation scenarios (cold start, load step, and pulsating exhaust flow).
publisherThe American Society of Mechanical Engineers (ASME)
titleA Research on Waste-Gated Turbine Performance Under Unsteady Flow Condition
typeJournal Paper
journal volume139
journal issue6
journal titleJournal of Engineering for Gas Turbines and Power
identifier doi10.1115/1.4035284
journal fristpage62603
journal lastpage062603-12
treeJournal of Engineering for Gas Turbines and Power:;2017:;volume( 139 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record