    Entrance Aspect Ratio Effect on S-Duct Inlet Performance at High-Subsonic Flow

    Source: Journal of Engineering for Gas Turbines and Power:;2017:;volume( 139 ):;issue: 005::page 52602
    Author:
    Asghar, Asad
    ,
    Stowe, Robert A.
    ,
    Allan, William D. E.
    ,
    Alexander, Derrick
    DOI: 10.1115/1.4035206
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper reports the internal performance evaluation of S-duct diffusers with different entrance aspect ratios as part of a parametric investigation of a generic S-duct inlet. The generic S-duct diffusers studied had a rectangular entrance (aspect ratios of 1.5 and 2.0) transitioning S-duct diffuser in high-subsonic (Mach number > 0.8) flow. The test section was manufactured using rapid prototyping to facilitate the parametric investigation of the geometry. Streamwise static pressure and exit-plane total pressure were measured in a test-rig using surface pressure taps and a five-probe rotating rake, respectively. The baseline and a variant were simulated through computational fluid dynamics (CFD). The investigation indicated the presence of streamwise and circumferential pressure gradients leading to a three-dimensional flow in the S-duct diffuser and to distortion at the exit plane. The static pressure recovery increased for the diffuser with the higher aspect ratio. Total pressure losses and circumferential and radial distortions at the exit plane were higher than that of the podded nacelle type of inlet. An increase in the total pressure recovery was observed for the increase in the aspect ratio for the baseline area ratio (1.57) S-ducts, but without a clear trend for the other area ratio (1.8) ducts. The work represents the development of a database on the performance of a particular type of generic inlet. This database will be useful for predicting the performance of aero-engines and air vehicles in high-subsonic flight.
    • Download: (2.575Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Entrance Aspect Ratio Effect on S-Duct Inlet Performance at High-Subsonic Flow

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4233699
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorAsghar, Asad
    contributor authorStowe, Robert A.
    contributor authorAllan, William D. E.
    contributor authorAlexander, Derrick
    date accessioned2017-11-25T07:15:50Z
    date available2017-11-25T07:15:50Z
    date copyright2017/4/1
    date issued2017
    identifier issn0742-4795
    identifier othergtp_139_05_052602.pdf
    identifier urihttp://138.201.223.254:8080/yetl1/handle/yetl/4233699
    description abstractThis paper reports the internal performance evaluation of S-duct diffusers with different entrance aspect ratios as part of a parametric investigation of a generic S-duct inlet. The generic S-duct diffusers studied had a rectangular entrance (aspect ratios of 1.5 and 2.0) transitioning S-duct diffuser in high-subsonic (Mach number > 0.8) flow. The test section was manufactured using rapid prototyping to facilitate the parametric investigation of the geometry. Streamwise static pressure and exit-plane total pressure were measured in a test-rig using surface pressure taps and a five-probe rotating rake, respectively. The baseline and a variant were simulated through computational fluid dynamics (CFD). The investigation indicated the presence of streamwise and circumferential pressure gradients leading to a three-dimensional flow in the S-duct diffuser and to distortion at the exit plane. The static pressure recovery increased for the diffuser with the higher aspect ratio. Total pressure losses and circumferential and radial distortions at the exit plane were higher than that of the podded nacelle type of inlet. An increase in the total pressure recovery was observed for the increase in the aspect ratio for the baseline area ratio (1.57) S-ducts, but without a clear trend for the other area ratio (1.8) ducts. The work represents the development of a database on the performance of a particular type of generic inlet. This database will be useful for predicting the performance of aero-engines and air vehicles in high-subsonic flight.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleEntrance Aspect Ratio Effect on S-Duct Inlet Performance at High-Subsonic Flow
    typeJournal Paper
    journal volume139
    journal issue5
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4035206
    journal fristpage52602
    journal lastpage052602-8
    treeJournal of Engineering for Gas Turbines and Power:;2017:;volume( 139 ):;issue: 005
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian