    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    A Method to Reduce the Energy Localization in Mistuned Bladed Disks by Application Specific Blade Pattern Arrangement

    Source: Journal of Engineering for Gas Turbines and Power:;2016:;volume( 138 ):;issue: 009::page 92502
    Author:
    Hohl, Andreas
    ,
    Wallaschek, Jأ¶rg
    DOI: 10.1115/1.4032739
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The focus of the paper is the analysis of mistuning, which are small deviations of the blade properties, e.g., due to manufacturing tolerances. The resonant amplitudes of turbine blades are very sensitive to these deviations which can lead to significantly increased vibratory response of some blades with the increased risk of high cycle fatigue. The main part of the paper discusses about the methods that can be used to find blade patterns which are insensitive to energy localization. The sensitivity of the forced response against harmonic mistuning, which is a harmonic alignment of the blades respective to the mistuning factors of the single blades, is examined. A previously developed reduced order model (ROM) is used to efficiently conduct Monte Carlo simulations (MCSs). Especially the influence of the variance of the harmonically mistuned blade patterns is discussed. On the basis of this analysis, rules are developed to suppress the energy localization. The rules are mainly focused on the alignment of the blades around the bladed disk. The approach also takes advantage of the special properties of harmonic mistuning patterns. An assignment of the blades to insensitive harmonic mistuning patterns with a specific variance and number of periods is used to reduce the maximum of the amplification factor of the forced response. A similar approach uses intentional mistuning patterns with different blade types which are aligned harmonically and are insensitive to an additional stochastic mistuning. In case of specific combinations of the dependent parameters, especially the variance of the mistuning factors and the number of periods, the energy localization can be reduced considerably.
    • Download: (3.372Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Method to Reduce the Energy Localization in Mistuned Bladed Disks by Application Specific Blade Pattern Arrangement

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/161168
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorHohl, Andreas
    contributor authorWallaschek, Jأ¶rg
    date accessioned2017-05-09T01:28:45Z
    date available2017-05-09T01:28:45Z
    date issued2016
    identifier issn1528-8919
    identifier othergtp_138_09_092502.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/161168
    description abstractThe focus of the paper is the analysis of mistuning, which are small deviations of the blade properties, e.g., due to manufacturing tolerances. The resonant amplitudes of turbine blades are very sensitive to these deviations which can lead to significantly increased vibratory response of some blades with the increased risk of high cycle fatigue. The main part of the paper discusses about the methods that can be used to find blade patterns which are insensitive to energy localization. The sensitivity of the forced response against harmonic mistuning, which is a harmonic alignment of the blades respective to the mistuning factors of the single blades, is examined. A previously developed reduced order model (ROM) is used to efficiently conduct Monte Carlo simulations (MCSs). Especially the influence of the variance of the harmonically mistuned blade patterns is discussed. On the basis of this analysis, rules are developed to suppress the energy localization. The rules are mainly focused on the alignment of the blades around the bladed disk. The approach also takes advantage of the special properties of harmonic mistuning patterns. An assignment of the blades to insensitive harmonic mistuning patterns with a specific variance and number of periods is used to reduce the maximum of the amplification factor of the forced response. A similar approach uses intentional mistuning patterns with different blade types which are aligned harmonically and are insensitive to an additional stochastic mistuning. In case of specific combinations of the dependent parameters, especially the variance of the mistuning factors and the number of periods, the energy localization can be reduced considerably.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Method to Reduce the Energy Localization in Mistuned Bladed Disks by Application Specific Blade Pattern Arrangement
    typeJournal Paper
    journal volume138
    journal issue9
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4032739
    journal fristpage92502
    journal lastpage92502
    identifier eissn0742-4795
    treeJournal of Engineering for Gas Turbines and Power:;2016:;volume( 138 ):;issue: 009
    contenttypeFulltext