Show simple item record

contributor authorWang, Shu
date accessioned2017-05-09T01:26:59Z
date available2017-05-09T01:26:59Z
date issued2016
identifier issn0022-0434
identifier otherds_138_04_041005.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/160671
description abstractHydromechanical compensators are often integrated with pistontype pumps to produce various control behavior, for example, pressure, loadsensing, power, or torque control. Various hydromechanical mechanisms (e.g., spring forces and load pressure) are found in the industry to ensure the desired effect of the system outputs: swash angle, discharge pressure, and input torque following the reference inputs. In a companion paper (Part I of this paper), a generic linearized statespace model is derived to investigate the pump dynamics and determine the design criteria and parameters. In the study, the statespace equations are used to propose and define the generic compensating control pump to conduct the similar strategies as hydromechanical pumps do. The different control purposes (pressure/flow/power compensating) are accomplished by only manipulating the generic regulate inputs given by an electrical proportional control valve. In the opencircuit pump, the generic controllers are proposed to generate these inputs by using one unique mechanical and electronic architecture to establish various purposes of flow, pressure, torque desired control, and even more control objectives. The controller is developed in accordance with the statespace representation and by following the models of the hydromechanical compensators that can facilitate the correlation verification. The proposed controllers are able to offer more intelligent and costsaving control strategies for opencircuit piston pumps. To achieve the similar performance as hydromechanical compensators do and implement the comparative study, control gains and settings in the controller can be determined from ones that hydromechanical compensators have. The difference is that electronic signals (swash plate position, pressure, etc.) work as feedbacks together with other control gains to regulate the input signals. For the different control purposes, control gains are able to be set conveniently for the various control operating conditions with combining the certain feedbacks on the same hardware platform that will be value efficient and capable of control intelligence. In the paper, results of predictions made by the model are presented and compared with some experimental data of hydromechanical designs. Further work on the advanced modelbased control and estimation is anticipated to be addressed.
publisherThe American Society of Mechanical Engineers (ASME)
titleGeneric Modeling and Control of an Open Circuit Piston Pump—Part II: Control Strategies and Designs
typeJournal Paper
journal volume138
journal issue4
journal titleJournal of Dynamic Systems, Measurement, and Control
identifier doi10.1115/1.4032554
journal fristpage41005
journal lastpage41005
identifier eissn1528-9028
treeJournal of Dynamic Systems, Measurement, and Control:;2016:;volume( 138 ):;issue: 004
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record