    Archive

    Neuromusculoskeletal Model Calibration Significantly Affects Predicted Knee Contact Forces for Walking

    Source: Journal of Biomechanical Engineering:;2016:;volume( 138 ):;issue: 008::page 81001
    Author:
    Serrancolأ­, Gil
    ,
    Kinney, Allison L.
    ,
    Fregly, Benjamin J.
    ,
    Font
    DOI: 10.1115/1.4033673
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Though walking impairments are prevalent in society, clinical treatments are often ineffective at restoring lost function. For this reason, researchers have begun to explore the use of patientspecific computational walking models to develop more effective treatments. However, the accuracy with which models can predict internal body forces in muscles and across joints depends on how well relevant model parameter values can be calibrated for the patient. This study investigated how knowledge of internal knee contact forces affects calibration of neuromusculoskeletal model parameter values and subsequent prediction of internal knee contact and leg muscle forces during walking. Model calibration was performed using a novel twolevel optimization procedure applied to six normal walking trials from the Fourth Grand Challenge Competition to Predict In Vivo Knee Loads. The outerlevel optimization adjusted timeinvariant model parameter values to minimize passive muscle forces, reserve actuator moments, and model parameter value changes with (Approach A) and without (Approach B) tracking of experimental knee contact forces. Using the current guess for model parameter values but no knee contact force information, the innerlevel optimization predicted timevarying muscle activations that were close to experimental muscle synergy patterns and consistent with the experimental inverse dynamic loads (both approaches). For all the six gait trials, Approach A predicted knee contact forces with high accuracy for both compartments (average correlation coefficient r = 0.99 and root mean square error (RMSE) = 52.6 N medial; average r = 0.95 and RMSE = 56.6 N lateral). In contrast, Approach B overpredicted contact force magnitude for both compartments (average RMSE = 323 N medial and 348 N lateral) and poorly matched contact force shape for the lateral compartment (average r = 0.90 medial and −0.10 lateral). Approach B had statistically higher lateral muscle forces and lateral optimal muscle fiber lengths but lower medial, central, and lateral normalized muscle fiber lengths compared to Approach A. These findings suggest that poorly calibrated model parameter values may be a major factor limiting the ability of neuromusculoskeletal models to predict knee contact and leg muscle forces accurately for walking.
    • Download: (2.006Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Neuromusculoskeletal Model Calibration Significantly Affects Predicted Knee Contact Forces for Walking

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/160432
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorSerrancolأ­, Gil
    contributor authorKinney, Allison L.
    contributor authorFregly, Benjamin J.
    contributor authorFont
    date accessioned2017-05-09T01:26:15Z
    date available2017-05-09T01:26:15Z
    date issued2016
    identifier issn0148-0731
    identifier otherfe_138_11_111101.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/160432
    description abstractThough walking impairments are prevalent in society, clinical treatments are often ineffective at restoring lost function. For this reason, researchers have begun to explore the use of patientspecific computational walking models to develop more effective treatments. However, the accuracy with which models can predict internal body forces in muscles and across joints depends on how well relevant model parameter values can be calibrated for the patient. This study investigated how knowledge of internal knee contact forces affects calibration of neuromusculoskeletal model parameter values and subsequent prediction of internal knee contact and leg muscle forces during walking. Model calibration was performed using a novel twolevel optimization procedure applied to six normal walking trials from the Fourth Grand Challenge Competition to Predict In Vivo Knee Loads. The outerlevel optimization adjusted timeinvariant model parameter values to minimize passive muscle forces, reserve actuator moments, and model parameter value changes with (Approach A) and without (Approach B) tracking of experimental knee contact forces. Using the current guess for model parameter values but no knee contact force information, the innerlevel optimization predicted timevarying muscle activations that were close to experimental muscle synergy patterns and consistent with the experimental inverse dynamic loads (both approaches). For all the six gait trials, Approach A predicted knee contact forces with high accuracy for both compartments (average correlation coefficient r = 0.99 and root mean square error (RMSE) = 52.6 N medial; average r = 0.95 and RMSE = 56.6 N lateral). In contrast, Approach B overpredicted contact force magnitude for both compartments (average RMSE = 323 N medial and 348 N lateral) and poorly matched contact force shape for the lateral compartment (average r = 0.90 medial and −0.10 lateral). Approach B had statistically higher lateral muscle forces and lateral optimal muscle fiber lengths but lower medial, central, and lateral normalized muscle fiber lengths compared to Approach A. These findings suggest that poorly calibrated model parameter values may be a major factor limiting the ability of neuromusculoskeletal models to predict knee contact and leg muscle forces accurately for walking.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleNeuromusculoskeletal Model Calibration Significantly Affects Predicted Knee Contact Forces for Walking
    typeJournal Paper
    journal volume138
    journal issue8
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4033673
    journal fristpage81001
    journal lastpage81001
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2016:;volume( 138 ):;issue: 008
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian