    Modeling the Human Tibiofemoral Joint Using Ex Vivo Determined Compliance Matrices

    Source: Journal of Biomechanical Engineering:;2016:;volume( 138 ):;issue: 006::page 61010
    Author:
    Lamberto, Giuliano
    ,
    Richard, Vincent
    ,
    Dumas, Raphaأ«l
    ,
    Valentini, Pier Paolo
    ,
    Pennestrأ¬, Ettore
    ,
    Lu, Tung
    ,
    Camomilla, Valentina
    ,
    Cappozzo, Aurelio
    DOI: 10.1115/1.4033480
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Several approaches have been used to devise a model of the human tibiofemoral joint for embedment in lower limb musculoskeletal models. However, no study has considered the use of cadaveric 6 أ— 6 compliance (or stiffness) matrices to model the tibiofemoral joint under normal or pathological conditions. The aim of this paper is to present a method to determine the compliance matrix of an ex vivo tibiofemoral joint for any given equilibrium pose. Experiments were carried out on a single ex vivo knee, first intact and, then, with the anterior cruciate ligament (ACL) transected. Controlled linear and angular displacements were imposed in single degreeoffreedom (DoF) tests to the specimen, and the resulting forces and moments were measured using an instrumented robotic arm. This was done starting from seven equilibrium poses characterized by the following flexion angles: 0 deg, 15 deg, 30 deg, 45 deg, 60 deg, 75 deg, and 90 deg. A compliance matrix for each of the selected equilibrium poses and for both the intact and ACLdeficient specimen was calculated. The matrix, embedding the experimental load–displacement relationship of the examined DoFs, was calculated using a linear least squares inversion based on a QR decomposition, assuming symmetric and positivedefined matrices. Single compliance matrix terms were in agreement with the literature. Results showed an overall increase of the compliance matrix terms due to the ACL transection (2.6 ratio for rotational terms at full extension) confirming its role in the joint stabilization. Validation experiments were carried out by performing a Lachman test (the tibia is pulled forward) under load control on both the intact and ACLdeficient knee and assessing the difference (error) between measured linear and angular displacements and those estimated using the appropriate compliance matrix. This error increased nonlinearly with respect to the values of the load. In particular, when an incremental posterior–anterior force up to 6 N was applied to the tibia of the intact specimen, the errors on the estimated linear and angular displacements were up to 0.6 mm and 1.5 deg, while for a force up to 18 N, the errors were 1.5 mm and 10.5 deg, respectively. In conclusion, the method used in this study may be a viable alternative to characterize the tibiofemoral loaddependent behavior in several applications.
    • Download: (1.771Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Modeling the Human Tibiofemoral Joint Using Ex Vivo Determined Compliance Matrices

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/160419
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorLamberto, Giuliano
    contributor authorRichard, Vincent
    contributor authorDumas, Raphaأ«l
    contributor authorValentini, Pier Paolo
    contributor authorPennestrأ¬, Ettore
    contributor authorLu, Tung
    contributor authorCamomilla, Valentina
    contributor authorCappozzo, Aurelio
    date accessioned2017-05-09T01:26:13Z
    date available2017-05-09T01:26:13Z
    date issued2016
    identifier issn0148-0731
    identifier otherjam_083_08_081002.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/160419
    description abstractSeveral approaches have been used to devise a model of the human tibiofemoral joint for embedment in lower limb musculoskeletal models. However, no study has considered the use of cadaveric 6 أ— 6 compliance (or stiffness) matrices to model the tibiofemoral joint under normal or pathological conditions. The aim of this paper is to present a method to determine the compliance matrix of an ex vivo tibiofemoral joint for any given equilibrium pose. Experiments were carried out on a single ex vivo knee, first intact and, then, with the anterior cruciate ligament (ACL) transected. Controlled linear and angular displacements were imposed in single degreeoffreedom (DoF) tests to the specimen, and the resulting forces and moments were measured using an instrumented robotic arm. This was done starting from seven equilibrium poses characterized by the following flexion angles: 0 deg, 15 deg, 30 deg, 45 deg, 60 deg, 75 deg, and 90 deg. A compliance matrix for each of the selected equilibrium poses and for both the intact and ACLdeficient specimen was calculated. The matrix, embedding the experimental load–displacement relationship of the examined DoFs, was calculated using a linear least squares inversion based on a QR decomposition, assuming symmetric and positivedefined matrices. Single compliance matrix terms were in agreement with the literature. Results showed an overall increase of the compliance matrix terms due to the ACL transection (2.6 ratio for rotational terms at full extension) confirming its role in the joint stabilization. Validation experiments were carried out by performing a Lachman test (the tibia is pulled forward) under load control on both the intact and ACLdeficient knee and assessing the difference (error) between measured linear and angular displacements and those estimated using the appropriate compliance matrix. This error increased nonlinearly with respect to the values of the load. In particular, when an incremental posterior–anterior force up to 6 N was applied to the tibia of the intact specimen, the errors on the estimated linear and angular displacements were up to 0.6 mm and 1.5 deg, while for a force up to 18 N, the errors were 1.5 mm and 10.5 deg, respectively. In conclusion, the method used in this study may be a viable alternative to characterize the tibiofemoral loaddependent behavior in several applications.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleModeling the Human Tibiofemoral Joint Using Ex Vivo Determined Compliance Matrices
    typeJournal Paper
    journal volume138
    journal issue6
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4033480
    journal fristpage61010
    journal lastpage61010
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2016:;volume( 138 ):;issue: 006
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian