Show simple item record

contributor authorLamberto, Giuliano
contributor authorRichard, Vincent
contributor authorDumas, Raphaأ«l
contributor authorValentini, Pier Paolo
contributor authorPennestrأ¬, Ettore
contributor authorLu, Tung
contributor authorCamomilla, Valentina
contributor authorCappozzo, Aurelio
date accessioned2017-05-09T01:26:13Z
date available2017-05-09T01:26:13Z
date issued2016
identifier issn0148-0731
identifier otherjam_083_08_081002.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/160419
description abstractSeveral approaches have been used to devise a model of the human tibiofemoral joint for embedment in lower limb musculoskeletal models. However, no study has considered the use of cadaveric 6 أ— 6 compliance (or stiffness) matrices to model the tibiofemoral joint under normal or pathological conditions. The aim of this paper is to present a method to determine the compliance matrix of an ex vivo tibiofemoral joint for any given equilibrium pose. Experiments were carried out on a single ex vivo knee, first intact and, then, with the anterior cruciate ligament (ACL) transected. Controlled linear and angular displacements were imposed in single degreeoffreedom (DoF) tests to the specimen, and the resulting forces and moments were measured using an instrumented robotic arm. This was done starting from seven equilibrium poses characterized by the following flexion angles: 0 deg, 15 deg, 30 deg, 45 deg, 60 deg, 75 deg, and 90 deg. A compliance matrix for each of the selected equilibrium poses and for both the intact and ACLdeficient specimen was calculated. The matrix, embedding the experimental load–displacement relationship of the examined DoFs, was calculated using a linear least squares inversion based on a QR decomposition, assuming symmetric and positivedefined matrices. Single compliance matrix terms were in agreement with the literature. Results showed an overall increase of the compliance matrix terms due to the ACL transection (2.6 ratio for rotational terms at full extension) confirming its role in the joint stabilization. Validation experiments were carried out by performing a Lachman test (the tibia is pulled forward) under load control on both the intact and ACLdeficient knee and assessing the difference (error) between measured linear and angular displacements and those estimated using the appropriate compliance matrix. This error increased nonlinearly with respect to the values of the load. In particular, when an incremental posterior–anterior force up to 6 N was applied to the tibia of the intact specimen, the errors on the estimated linear and angular displacements were up to 0.6 mm and 1.5 deg, while for a force up to 18 N, the errors were 1.5 mm and 10.5 deg, respectively. In conclusion, the method used in this study may be a viable alternative to characterize the tibiofemoral loaddependent behavior in several applications.
publisherThe American Society of Mechanical Engineers (ASME)
titleModeling the Human Tibiofemoral Joint Using Ex Vivo Determined Compliance Matrices
typeJournal Paper
journal volume138
journal issue6
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.4033480
journal fristpage61010
journal lastpage61010
identifier eissn1528-8951
treeJournal of Biomechanical Engineering:;2016:;volume( 138 ):;issue: 006
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record