    Numerical Investigations on the Leakage and Rotordynamic Characteristics of Pocket Damper Seals—Part II: Effects of Partition Wall Type, Partition Wall Number, and Cavity Depth

    Source: Journal of Engineering for Gas Turbines and Power:;2015:;volume( 137 ):;issue: 003::page 32504
    Author:
    Li, Zhigang
    ,
    Li, Jun
    ,
    Feng, Zhenping
    DOI: 10.1115/1.4028374
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Effects of partition wall type, partition wall number and cavity depth on the leakage and rotordynamic characteristics of the pocket damper seal (PDS) were numerically investigated using a presented 3D transient computational fluid dynamics (CFD) method based on the multifrequency elliptical whirling orbit model. The accuracy and availability of this transient CFD method and the multifrequency elliptical whirling orbit model were demonstrated with the experimental data of the experimental eightbladed fully partitioned pocket damper seal (FPDS). The leakage flow rates and frequencydependent rotordynamic coefficients of PDS were computed for two types of partition wall (namely conventional PDS and fully partitioned PDS), four partition wall numbers including the labyrinth seal (no partition wall) and six cavity depths including the plain smooth seal (zero cavity depth) at operational conditions with or without inlet preswirl and 15,000 rpm rotational speed. The numerical results show that the FPDS has the similar leakage performance and more superior stability capacity than the conventional PDS. The FPDS possesses slightly larger leakage flow rate (∼2.6–4.0% larger) compared to the labyrinth seal. Eight is a preferable value for the partition wall number to gain the best leakage performance of the FPDS with the least manufacturing cost. The FPDS possesses significantly larger stiffness and damping than the labyrinth seal. Increasing partition wall number results in a significant increase in the direct stiffness but limited desirable effect on the effective damping. The FPDS possesses the lowest leakage flow rate when the cavity depth is about 2.0 mm. Compared to the plain smooth seal, the FPDS possesses larger positive direct stiffness and significantly less direct damping and effective damping. Increasing cavity depth results in a significant decrease in the stabilizing direct damping and the magnitude of the destabilizing crosscoupling stiffness. H= 3.175 mm is a preferable value of the cavity depth for which the effective damping of the FPDS is largest, especially for the concerned frequencies (80–120 Hz) where most multistage highpressure centrifugal compressors have stability problem.
    • Download: (5.490Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Numerical Investigations on the Leakage and Rotordynamic Characteristics of Pocket Damper Seals—Part II: Effects of Partition Wall Type, Partition Wall Number, and Cavity Depth

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/157891
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorLi, Zhigang
    contributor authorLi, Jun
    contributor authorFeng, Zhenping
    date accessioned2017-05-09T01:17:36Z
    date available2017-05-09T01:17:36Z
    date issued2015
    identifier issn1528-8919
    identifier othergtp_137_03_032504.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/157891
    description abstractEffects of partition wall type, partition wall number and cavity depth on the leakage and rotordynamic characteristics of the pocket damper seal (PDS) were numerically investigated using a presented 3D transient computational fluid dynamics (CFD) method based on the multifrequency elliptical whirling orbit model. The accuracy and availability of this transient CFD method and the multifrequency elliptical whirling orbit model were demonstrated with the experimental data of the experimental eightbladed fully partitioned pocket damper seal (FPDS). The leakage flow rates and frequencydependent rotordynamic coefficients of PDS were computed for two types of partition wall (namely conventional PDS and fully partitioned PDS), four partition wall numbers including the labyrinth seal (no partition wall) and six cavity depths including the plain smooth seal (zero cavity depth) at operational conditions with or without inlet preswirl and 15,000 rpm rotational speed. The numerical results show that the FPDS has the similar leakage performance and more superior stability capacity than the conventional PDS. The FPDS possesses slightly larger leakage flow rate (∼2.6–4.0% larger) compared to the labyrinth seal. Eight is a preferable value for the partition wall number to gain the best leakage performance of the FPDS with the least manufacturing cost. The FPDS possesses significantly larger stiffness and damping than the labyrinth seal. Increasing partition wall number results in a significant increase in the direct stiffness but limited desirable effect on the effective damping. The FPDS possesses the lowest leakage flow rate when the cavity depth is about 2.0 mm. Compared to the plain smooth seal, the FPDS possesses larger positive direct stiffness and significantly less direct damping and effective damping. Increasing cavity depth results in a significant decrease in the stabilizing direct damping and the magnitude of the destabilizing crosscoupling stiffness. H= 3.175 mm is a preferable value of the cavity depth for which the effective damping of the FPDS is largest, especially for the concerned frequencies (80–120 Hz) where most multistage highpressure centrifugal compressors have stability problem.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleNumerical Investigations on the Leakage and Rotordynamic Characteristics of Pocket Damper Seals—Part II: Effects of Partition Wall Type, Partition Wall Number, and Cavity Depth
    typeJournal Paper
    journal volume137
    journal issue3
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4028374
    journal fristpage32504
    journal lastpage32504
    identifier eissn0742-4795
    treeJournal of Engineering for Gas Turbines and Power:;2015:;volume( 137 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian