    Archive

    Load Rejection Tests and Their Dynamic Simulations With a 150 kW Class Microsteam Turbine

    Source: Journal of Engineering for Gas Turbines and Power:;2013:;volume( 135 ):;issue: 005::page 52301
    Author:
    Nakano, Susumu
    ,
    Tsubouchi, Kuniyoshi
    ,
    Shiraiwa, Hiroyuki
    ,
    Hayashi, Kazutaka
    ,
    Yamada, Hiroyuki
    DOI: 10.1115/1.4007773
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A simulation method for load rejection with a 150 kW class radial inflow steam turbine system was proposed to determine over rotational speed at load rejection. Simulations were carried out for several parameters of valves which are operated in an emergency. In addition, load rejection tests were carried out to confirm the machine reliability and to obtain results for comparison with the simulation results. Simulation results show that operation delay times of the steam release and vacuum break valves greatly affect over rotational speed at load rejection. Load rejection tests were done for generator outputs from 69 kW to 113 kW. Maximum over rotational speed of 54,160 rpm was measured at the generator output of 113 kW. Over rotational speed calculated by the dynamic simulation has relatively good agreement with the result for the operation delay time of 0.21 s. If the operation delay time of the steam release valves are kept as 0.21 s at the load rejection for the rated load of 150 kW, the over rotational speed is suppressed within 55,200 rpm which is less than the allowed rotational speed of 56,100 rpm.
    • Download: (1.259Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Load Rejection Tests and Their Dynamic Simulations With a 150 kW Class Microsteam Turbine

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/151606
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorNakano, Susumu
    contributor authorTsubouchi, Kuniyoshi
    contributor authorShiraiwa, Hiroyuki
    contributor authorHayashi, Kazutaka
    contributor authorYamada, Hiroyuki
    date accessioned2017-05-09T00:58:13Z
    date available2017-05-09T00:58:13Z
    date issued2013
    identifier issn1528-8919
    identifier othergtp_135_5_052301.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/151606
    description abstractA simulation method for load rejection with a 150 kW class radial inflow steam turbine system was proposed to determine over rotational speed at load rejection. Simulations were carried out for several parameters of valves which are operated in an emergency. In addition, load rejection tests were carried out to confirm the machine reliability and to obtain results for comparison with the simulation results. Simulation results show that operation delay times of the steam release and vacuum break valves greatly affect over rotational speed at load rejection. Load rejection tests were done for generator outputs from 69 kW to 113 kW. Maximum over rotational speed of 54,160 rpm was measured at the generator output of 113 kW. Over rotational speed calculated by the dynamic simulation has relatively good agreement with the result for the operation delay time of 0.21 s. If the operation delay time of the steam release valves are kept as 0.21 s at the load rejection for the rated load of 150 kW, the over rotational speed is suppressed within 55,200 rpm which is less than the allowed rotational speed of 56,100 rpm.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleLoad Rejection Tests and Their Dynamic Simulations With a 150 kW Class Microsteam Turbine
    typeJournal Paper
    journal volume135
    journal issue5
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.4007773
    journal fristpage52301
    journal lastpage52301
    identifier eissn0742-4795
    treeJournal of Engineering for Gas Turbines and Power:;2013:;volume( 135 ):;issue: 005
    contenttypeFulltext