Laminar Flame Speed and Ignition Delay Time Data for the Kinetic Modeling of Hydrogen and Syngas Fuel BlendsSource: Journal of Engineering for Gas Turbines and Power:;2013:;volume( 135 ):;issue: 002::page 21503Author:Krejci, Michael C.
,
Mathieu, Olivier
,
Vissotski, Andrew J.
,
Ravi, Sankaranarayanan
,
Sikes, Travis G.
,
Petersen, Eric L.
,
Kأ©rmonأ¨s, Alan
,
Metcalfe, Wayne
,
Curran, Henry J.
DOI: 10.1115/1.4007737Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Laminar flame speeds and ignition delay times have been measured for hydrogen and various compositions of H2/CO (syngas) at elevated pressures and elevated temperatures. Two constantvolume cylindrical vessels were used to visualize the spherical growth of the flame through the use of a schlieren optical setup to measure the laminar flame speed of the mixture. Hydrogen experiments were performed at initial pressures up to 10 atm and initial temperatures up to 443 K. A syngas composition of 50/50 by volume was chosen to demonstrate the effect of carbon monoxide on H2O2 chemical kinetics at standard temperature and pressures up to 10 atm. All atmospheric mixtures were diluted with standard air, while all elevatedpressure experiments were diluted with a He:O2 ratio of 7:1 to minimize instabilities. The laminar flame speed measurements of hydrogen and syngas are compared to available literature data over a wide range of equivalence ratios, where good agreement can be seen with several data sets. Additionally, an improved chemical kinetics model is shown for all conditions within the current study. The model and the data presented herein agree well, which demonstrates the continual, improved accuracy of the chemical kinetics model. A highpressure shock tube was used to measure ignition delay times for several baseline compositions of syngas at three pressures across a wide range of temperatures. The compositions of syngas (H2/CO) by volume presented in this study included 80/20, 50/50, 40/60, 20/80, and 10/90, all of which are compared to previously published ignition delay times from a hydrogenoxygen mixture to demonstrate the effect of carbon monoxide addition. Generally, an increase in carbon monoxide increases the ignition delay time, but there does seem to be a pressure dependency. At low temperatures and pressures higher than about 12 atm, the ignition delay times appear to be indistinguishable with an increase in carbon monoxide. However, at high temperatures the relative composition of H2 and CO has a strong influence on ignition delay times. Model agreement is good across the range of the study, particularly at the elevated pressures.
|
Show full item record
contributor author | Krejci, Michael C. | |
contributor author | Mathieu, Olivier | |
contributor author | Vissotski, Andrew J. | |
contributor author | Ravi, Sankaranarayanan | |
contributor author | Sikes, Travis G. | |
contributor author | Petersen, Eric L. | |
contributor author | Kأ©rmonأ¨s, Alan | |
contributor author | Metcalfe, Wayne | |
contributor author | Curran, Henry J. | |
date accessioned | 2017-05-09T00:58:02Z | |
date available | 2017-05-09T00:58:02Z | |
date issued | 2013 | |
identifier issn | 1528-8919 | |
identifier other | gtp_135_2_021503.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/151549 | |
description abstract | Laminar flame speeds and ignition delay times have been measured for hydrogen and various compositions of H2/CO (syngas) at elevated pressures and elevated temperatures. Two constantvolume cylindrical vessels were used to visualize the spherical growth of the flame through the use of a schlieren optical setup to measure the laminar flame speed of the mixture. Hydrogen experiments were performed at initial pressures up to 10 atm and initial temperatures up to 443 K. A syngas composition of 50/50 by volume was chosen to demonstrate the effect of carbon monoxide on H2O2 chemical kinetics at standard temperature and pressures up to 10 atm. All atmospheric mixtures were diluted with standard air, while all elevatedpressure experiments were diluted with a He:O2 ratio of 7:1 to minimize instabilities. The laminar flame speed measurements of hydrogen and syngas are compared to available literature data over a wide range of equivalence ratios, where good agreement can be seen with several data sets. Additionally, an improved chemical kinetics model is shown for all conditions within the current study. The model and the data presented herein agree well, which demonstrates the continual, improved accuracy of the chemical kinetics model. A highpressure shock tube was used to measure ignition delay times for several baseline compositions of syngas at three pressures across a wide range of temperatures. The compositions of syngas (H2/CO) by volume presented in this study included 80/20, 50/50, 40/60, 20/80, and 10/90, all of which are compared to previously published ignition delay times from a hydrogenoxygen mixture to demonstrate the effect of carbon monoxide addition. Generally, an increase in carbon monoxide increases the ignition delay time, but there does seem to be a pressure dependency. At low temperatures and pressures higher than about 12 atm, the ignition delay times appear to be indistinguishable with an increase in carbon monoxide. However, at high temperatures the relative composition of H2 and CO has a strong influence on ignition delay times. Model agreement is good across the range of the study, particularly at the elevated pressures. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Laminar Flame Speed and Ignition Delay Time Data for the Kinetic Modeling of Hydrogen and Syngas Fuel Blends | |
type | Journal Paper | |
journal volume | 135 | |
journal issue | 2 | |
journal title | Journal of Engineering for Gas Turbines and Power | |
identifier doi | 10.1115/1.4007737 | |
journal fristpage | 21503 | |
journal lastpage | 21503 | |
identifier eissn | 0742-4795 | |
tree | Journal of Engineering for Gas Turbines and Power:;2013:;volume( 135 ):;issue: 002 | |
contenttype | Fulltext |