    Archive

    Measurement of Total Hemispherical Emissivity Using Vacuum Guarded Hot Plate

    Source: Journal of Heat Transfer:;2012:;volume( 134 ):;issue: 011::page 114501
    Author:
    Jongmin Kim
    ,
    Choongyo Jang
    ,
    Tae-Ho Song
    DOI: 10.1115/1.4005748
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In this paper, a new measurement method for the total hemispherical emissivity of surfaces is introduced. A vacuum guarded hot plate apparatus is developed and it is employed for the emissivity measurement. Al, Ag, Au, and Ni coatings and STS 304 plate are used as the specimen. Measured total hemispherical emissivities are 0.05–0.24 with 8.1% uncertainty at most. This proves the reliability of current method even for highly reflective surfaces.
    keyword(s): Vacuum , Emissivity , Uncertainty AND Coatings ,
    • Download: (677.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Measurement of Total Hemispherical Emissivity Using Vacuum Guarded Hot Plate

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/149322
    Collections
    • Journal of Heat Transfer

    Show full item record

    contributor authorJongmin Kim
    contributor authorChoongyo Jang
    contributor authorTae-Ho Song
    date accessioned2017-05-09T00:51:55Z
    date available2017-05-09T00:51:55Z
    date copyrightNovember, 2012
    date issued2012
    identifier issn0022-1481
    identifier otherJHTRAO-926057#114501_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/149322
    description abstractIn this paper, a new measurement method for the total hemispherical emissivity of surfaces is introduced. A vacuum guarded hot plate apparatus is developed and it is employed for the emissivity measurement. Al, Ag, Au, and Ni coatings and STS 304 plate are used as the specimen. Measured total hemispherical emissivities are 0.05–0.24 with 8.1% uncertainty at most. This proves the reliability of current method even for highly reflective surfaces.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleMeasurement of Total Hemispherical Emissivity Using Vacuum Guarded Hot Plate
    typeJournal Paper
    journal volume134
    journal issue11
    journal titleJournal of Heat Transfer
    identifier doi10.1115/1.4005748
    journal fristpage114501
    identifier eissn1528-8943
    keywordsVacuum
    keywordsEmissivity
    keywordsUncertainty AND Coatings
    treeJournal of Heat Transfer:;2012:;volume( 134 ):;issue: 011
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian