Show simple item record

contributor authorJongmin Kim
contributor authorChoongyo Jang
contributor authorTae-Ho Song
date accessioned2017-05-09T00:51:55Z
date available2017-05-09T00:51:55Z
date copyrightNovember, 2012
date issued2012
identifier issn0022-1481
identifier otherJHTRAO-926057#114501_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/149322
description abstractIn this paper, a new measurement method for the total hemispherical emissivity of surfaces is introduced. A vacuum guarded hot plate apparatus is developed and it is employed for the emissivity measurement. Al, Ag, Au, and Ni coatings and STS 304 plate are used as the specimen. Measured total hemispherical emissivities are 0.05–0.24 with 8.1% uncertainty at most. This proves the reliability of current method even for highly reflective surfaces.
publisherThe American Society of Mechanical Engineers (ASME)
titleMeasurement of Total Hemispherical Emissivity Using Vacuum Guarded Hot Plate
typeJournal Paper
journal volume134
journal issue11
journal titleJournal of Heat Transfer
identifier doi10.1115/1.4005748
journal fristpage114501
identifier eissn1528-8943
keywordsVacuum
keywordsEmissivity
keywordsUncertainty AND Coatings
treeJournal of Heat Transfer:;2012:;volume( 134 ):;issue: 011
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record