YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Biomechanical Engineering
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Hydrodynamic Effects of Compliance Mismatch in Stented Arteries

    Source: Journal of Biomechanical Engineering:;2011:;volume( 133 ):;issue: 002::page 21008
    Author:
    N. K. C. Selvarasu
    ,
    Danesh K. Tafti
    ,
    Pavlos P. Vlachos
    DOI: 10.1115/1.4003319
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Cardiovascular diseases are the number one cause of death in the world, making the understanding of hemodynamics and development of treatment options imperative. The most common modality for treatment of occlusive coronary artery diseases is the use of stents. Stent design profoundly influences the postprocedural hemodynamic and solid mechanical environment of the stented artery. However, despite their wide acceptance, the incidence of stent late restenosis is still high (, 2010, “Coronary Stent Thrombosis in the Current Era: Challenges and Opportunities for Treatment,” Current Treatment Options in Cardiovascular Medicine, 12(1), pp. 46–57), and it is most prevailing at the proximal and distal ends of the stent. In this work, we focus our investigation on the localized hemodynamic effects of compliance mismatch due to the presence of a stent in an artery. The compliance mismatch in a stented artery is maximized at the proximal and distal ends of the stent. Hence, it is our objective to understand and reveal the mechanism by which changes in compliance contribute to the generation of nonphysiological wall shear stress (WSS). Such adverse hemodynamic conditions could have an effect on the onset of restenosis. Three-dimensional, spatiotemporally resolved computational fluid dynamics simulations of pulsatile flow with fluid-structure interaction were carried out for a simplified coronary artery with physiologically relevant flow parameters. A model with uniform elastic modulus is used as the baseline control case. In order to study the effect of compliance variation on local hemodynamics, this baseline model is compared with models where the elastic modulus was increased by two-, five-, and tenfold in the middle of the vessel. The simulations provided detailed information regarding the recirculation zone dynamics formed during flow reversals. The results suggest that discontinuities in compliance cause critical changes in local hemodynamics, namely, altering the local pressure and velocity gradients. The change in pressure gradient at the discontinuity was as high as 90%. The corresponding changes in WSS and oscillatory shear index calculated were 9% and 15%, respectively. We demonstrate that these changes are attributed to the physical mechanism associating the pressure gradient discontinuities to the production of vorticity (vorticity flux) due to the presence of the stent. The pressure gradient discontinuities and augmented vorticity flux are affecting the wall shear stresses. As a result, this work reveals how compliance variations act to modify the near wall hemodynamics of stented arteries.
    • Download: (1.176Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Hydrodynamic Effects of Compliance Mismatch in Stented Arteries

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/145487
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorN. K. C. Selvarasu
    contributor authorDanesh K. Tafti
    contributor authorPavlos P. Vlachos
    date accessioned2017-05-09T00:42:36Z
    date available2017-05-09T00:42:36Z
    date copyrightFebruary, 2011
    date issued2011
    identifier issn0148-0731
    identifier otherJBENDY-27194#021008_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/145487
    description abstractCardiovascular diseases are the number one cause of death in the world, making the understanding of hemodynamics and development of treatment options imperative. The most common modality for treatment of occlusive coronary artery diseases is the use of stents. Stent design profoundly influences the postprocedural hemodynamic and solid mechanical environment of the stented artery. However, despite their wide acceptance, the incidence of stent late restenosis is still high (, 2010, “Coronary Stent Thrombosis in the Current Era: Challenges and Opportunities for Treatment,” Current Treatment Options in Cardiovascular Medicine, 12(1), pp. 46–57), and it is most prevailing at the proximal and distal ends of the stent. In this work, we focus our investigation on the localized hemodynamic effects of compliance mismatch due to the presence of a stent in an artery. The compliance mismatch in a stented artery is maximized at the proximal and distal ends of the stent. Hence, it is our objective to understand and reveal the mechanism by which changes in compliance contribute to the generation of nonphysiological wall shear stress (WSS). Such adverse hemodynamic conditions could have an effect on the onset of restenosis. Three-dimensional, spatiotemporally resolved computational fluid dynamics simulations of pulsatile flow with fluid-structure interaction were carried out for a simplified coronary artery with physiologically relevant flow parameters. A model with uniform elastic modulus is used as the baseline control case. In order to study the effect of compliance variation on local hemodynamics, this baseline model is compared with models where the elastic modulus was increased by two-, five-, and tenfold in the middle of the vessel. The simulations provided detailed information regarding the recirculation zone dynamics formed during flow reversals. The results suggest that discontinuities in compliance cause critical changes in local hemodynamics, namely, altering the local pressure and velocity gradients. The change in pressure gradient at the discontinuity was as high as 90%. The corresponding changes in WSS and oscillatory shear index calculated were 9% and 15%, respectively. We demonstrate that these changes are attributed to the physical mechanism associating the pressure gradient discontinuities to the production of vorticity (vorticity flux) due to the presence of the stent. The pressure gradient discontinuities and augmented vorticity flux are affecting the wall shear stresses. As a result, this work reveals how compliance variations act to modify the near wall hemodynamics of stented arteries.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleHydrodynamic Effects of Compliance Mismatch in Stented Arteries
    typeJournal Paper
    journal volume133
    journal issue2
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.4003319
    journal fristpage21008
    identifier eissn1528-8951
    treeJournal of Biomechanical Engineering:;2011:;volume( 133 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian