    Vapor Chamber Acting as a Heat Spreader for Power Module Cooling

    Source: Journal of Thermal Science and Engineering Applications:;2009:;volume( 001 ):;issue: 002::page 21003
    Author:
    Y. P. Zhang
    ,
    X. L. Yu
    ,
    Q. K. Feng
    ,
    L. H. Zhang
    DOI: 10.1115/1.4000285
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: This paper presents an integrated power electronics module with a vapor chamber (VC) acting as a heat spreader to transfer the heat from the insulated gate bipolar transistor (IGBT) module to the base of the heat-sink. The novel VC integrated in a power module instead of a metal substrate is proposed. Compared with a conventional metal heat spreader, the VC significantly diffuses the concentrated heat source to a larger condensing area. The experimental results indicate that the VC based heat-sink will maintain the IGBT junction temperature 20°C cooler than a non-VC based heat-sink with high power density. The junction-to-case thermal resistance of the power module based on the VC is about 50% less than that of the power module based on a copper substrate with the same weight. The chip overshooting temperature of the copper substrate module with the same weight goes beyond 10°C against the junction temperature of the VC module at a given impulse power of 225 W. Consequently, thanks to a longer time duration to reach the same temperature, a power surge for the chip can be avoided and the ability to resist thermal impact during the VC module startup can be improved as well. The investigation shows that the VC power module is an excellent candidate for the original metal substrate, especially for an integrated power module with high power density.
    keyword(s): Weight (Mass) , Heat , Temperature , Cooling , Vapors , Copper , Heat sinks , Junctions , Thermal resistance , Heat flux , Flat heat pipes , Metals , Heat transfer , Heat pipes AND Electronics ,
    • Download: (593.4Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Vapor Chamber Acting as a Heat Spreader for Power Module Cooling

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/141998
    Collections
    • Journal of Thermal Science and Engineering Applications

    Show full item record

    contributor authorY. P. Zhang
    contributor authorX. L. Yu
    contributor authorQ. K. Feng
    contributor authorL. H. Zhang
    date accessioned2017-05-09T00:35:27Z
    date available2017-05-09T00:35:27Z
    date copyrightJune, 2009
    date issued2009
    identifier issn1948-5085
    identifier otherJTSEBV-28805#021003_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/141998
    description abstractThis paper presents an integrated power electronics module with a vapor chamber (VC) acting as a heat spreader to transfer the heat from the insulated gate bipolar transistor (IGBT) module to the base of the heat-sink. The novel VC integrated in a power module instead of a metal substrate is proposed. Compared with a conventional metal heat spreader, the VC significantly diffuses the concentrated heat source to a larger condensing area. The experimental results indicate that the VC based heat-sink will maintain the IGBT junction temperature 20°C cooler than a non-VC based heat-sink with high power density. The junction-to-case thermal resistance of the power module based on the VC is about 50% less than that of the power module based on a copper substrate with the same weight. The chip overshooting temperature of the copper substrate module with the same weight goes beyond 10°C against the junction temperature of the VC module at a given impulse power of 225 W. Consequently, thanks to a longer time duration to reach the same temperature, a power surge for the chip can be avoided and the ability to resist thermal impact during the VC module startup can be improved as well. The investigation shows that the VC power module is an excellent candidate for the original metal substrate, especially for an integrated power module with high power density.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleVapor Chamber Acting as a Heat Spreader for Power Module Cooling
    typeJournal Paper
    journal volume1
    journal issue2
    journal titleJournal of Thermal Science and Engineering Applications
    identifier doi10.1115/1.4000285
    journal fristpage21003
    identifier eissn1948-5093
    keywordsWeight (Mass)
    keywordsHeat
    keywordsTemperature
    keywordsCooling
    keywordsVapors
    keywordsCopper
    keywordsHeat sinks
    keywordsJunctions
    keywordsThermal resistance
    keywordsHeat flux
    keywordsFlat heat pipes
    keywordsMetals
    keywordsHeat transfer
    keywordsHeat pipes AND Electronics
    treeJournal of Thermal Science and Engineering Applications:;2009:;volume( 001 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian