    Design and Performance Evaluation of a Trigeneration System Incorporating Hydraulic Storage and an Inverted Brayton Cycle

    Source: Journal of Engineering for Gas Turbines and Power:;2009:;volume( 131 ):;issue: 001::page 12302
    Author:
    Matthew Blieske
    ,
    J. E. D. Gauthier
    ,
    X. Huang
    DOI: 10.1115/1.2966420
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: To bring the economic benefit of trigeneration to small-scale users without incorporating expensive components, an inverted Brayton cycle (IBC) is employed, which makes use of the expander section already present in a microturbine. An air accumulator provides pressurized air, which is passed through the expander section of the same microturbine used to charge the accumulator. The air passing through the IBC is cooled due to expansion, simultaneously providing power and cooling the flow. As the microturbine is indirectly fired, the flow passing through the engine or IBC can be directly vented into the household—eliminating the need for additional heat exchangers. The size of the cycle studied is on the order of 10 kW(e), suitable for a domestic household; however, the system is easily scaled for larger commercial applications. The majority of the components in the system being studied are “off the shelf” products. A feasibility study was conducted to ensure that the proposed system is economically competitive with systems currently used, such as individual generation provided by an air conditioner (A/C), a high efficiency natural gas (NG) furnace, and grid power. Simulations were run for a full year based on the actual external temperature and the electrical and thermal loads for a single family detached dwelling located in Winnipeg, Canada. Performance data were generated using MATLAB ™ while the economic performance was determined with time-based simulations conducted using SIMULINK ™. The system is designed to allow energy islanding by providing for all household energy needs throughout the year; however, integration with a power grid is optional. It was found that the operating costs for the proposed trigeneration system in an energy islanding mode of operation were equivalent to or less than individual generation (A/C unit, NG furnace, and grid power) during heating modes of operation and were more expensive for cooling modes of operation. The yearly energy cost for the trigeneration system exceeded the individual generation costs by 30–40%; however, there remains much room for improvement to the trigeneration concept. All economic data were based on fair market energy prices as found in central Canada.
    keyword(s): Flow (Dynamics) , Temperature , Cooling , Simulation , Stress , Design , Microturbines , Brayton cycle , Secondary cells , Heat exchangers , Heating , Compressors , Cycles AND Turbomachinery ,
    • Download: (1.018Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Design and Performance Evaluation of a Trigeneration System Incorporating Hydraulic Storage and an Inverted Brayton Cycle

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/140538
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorMatthew Blieske
    contributor authorJ. E. D. Gauthier
    contributor authorX. Huang
    date accessioned2017-05-09T00:32:48Z
    date available2017-05-09T00:32:48Z
    date copyrightJanuary, 2009
    date issued2009
    identifier issn1528-8919
    identifier otherJETPEZ-27051#012302_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/140538
    description abstractTo bring the economic benefit of trigeneration to small-scale users without incorporating expensive components, an inverted Brayton cycle (IBC) is employed, which makes use of the expander section already present in a microturbine. An air accumulator provides pressurized air, which is passed through the expander section of the same microturbine used to charge the accumulator. The air passing through the IBC is cooled due to expansion, simultaneously providing power and cooling the flow. As the microturbine is indirectly fired, the flow passing through the engine or IBC can be directly vented into the household—eliminating the need for additional heat exchangers. The size of the cycle studied is on the order of 10 kW(e), suitable for a domestic household; however, the system is easily scaled for larger commercial applications. The majority of the components in the system being studied are “off the shelf” products. A feasibility study was conducted to ensure that the proposed system is economically competitive with systems currently used, such as individual generation provided by an air conditioner (A/C), a high efficiency natural gas (NG) furnace, and grid power. Simulations were run for a full year based on the actual external temperature and the electrical and thermal loads for a single family detached dwelling located in Winnipeg, Canada. Performance data were generated using MATLAB ™ while the economic performance was determined with time-based simulations conducted using SIMULINK ™. The system is designed to allow energy islanding by providing for all household energy needs throughout the year; however, integration with a power grid is optional. It was found that the operating costs for the proposed trigeneration system in an energy islanding mode of operation were equivalent to or less than individual generation (A/C unit, NG furnace, and grid power) during heating modes of operation and were more expensive for cooling modes of operation. The yearly energy cost for the trigeneration system exceeded the individual generation costs by 30–40%; however, there remains much room for improvement to the trigeneration concept. All economic data were based on fair market energy prices as found in central Canada.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDesign and Performance Evaluation of a Trigeneration System Incorporating Hydraulic Storage and an Inverted Brayton Cycle
    typeJournal Paper
    journal volume131
    journal issue1
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.2966420
    journal fristpage12302
    identifier eissn0742-4795
    keywordsFlow (Dynamics)
    keywordsTemperature
    keywordsCooling
    keywordsSimulation
    keywordsStress
    keywordsDesign
    keywordsMicroturbines
    keywordsBrayton cycle
    keywordsSecondary cells
    keywordsHeat exchangers
    keywordsHeating
    keywordsCompressors
    keywordsCycles AND Turbomachinery
    treeJournal of Engineering for Gas Turbines and Power:;2009:;volume( 131 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian