description abstractAn analytical expression for the heat transport capability of micro heat pipe is derived. The vapor continuum limitation has been considered in deriving the heat transport capability of a micro heat pipe. As the micro heat pipe uses sharp-cornered square, triangular, or other polygonal channels that can serve as capillary arteries, its transport capability depends on the capillary limit. It has been shown that the operating limit of the micro heat pipe depends on the vapor continuum limitation, capillary limit, and the gravity.
publisherThe American Society of Mechanical Engineers (ASME)
titleHeat Transfer Limitation of a Micro Heat Pipe
typeJournal Paper
journal volume131
journal issue2
journal titleJournal of Electronic Packaging
identifier doi10.1115/1.3103970
journal fristpage24502
identifier eissn1043-7398
keywordsHeat
keywordsHeat transfer
keywordsHeat pipes
keywordsVapors
keywordsGravity (Force)
keywordsChannels (Hydraulic engineering) AND Equations
treeJournal of Electronic Packaging:;2009:;volume( 131 ):;issue: 002