    Squeeze Film Damper With a Mechanical End Seal: Experimental Force Coefficients Derived From Circular Centered Orbits

    Source: Journal of Engineering for Gas Turbines and Power:;2008:;volume( 130 ):;issue: 004::page 42505
    Author:
    Luis San Andrés
    ,
    Adolfo Delgado
    DOI: 10.1115/1.2800345
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The paper presents parameter identification measurements conducted on a squeeze film damper (SFD) featuring a nonrotating mechanical seal that effectively eliminates lubricant side leakage. The SFD-seal arrangement generates dissipative forces due to viscous and dry-friction effects from the lubricant film and surfaces in contact, respectively. The test damper reproduces an aircraft application that must contain the lubricant for extended periods of time. The test damper journal is 2.54cm in length and 12.7cm in diameter, with a nominal clearance of 0.127mm. The damper feed end opens to a plenum filled with lubricant, and at its discharge grooved section, four orifice ports evacuate the lubricant. In earlier publications, single frequency force excitation tests were conducted, without and with lubricant in the squeeze film land, to determine the seal dry-friction force and viscous damping force coefficients. Presently, further measurements are conducted to identify the test system and SFD force coefficients using two sets of flow restrictor orifice sizes (2.8mm and 1.1mm in diameter). The flow restrictors regulate the discharge flow area and thus control the oil flow through the squeeze film. The experiments also include measurements of dynamic pressures at the squeeze film land and at the discharge groove. The magnitude of dynamic pressure in the squeeze film land is nearly identical for both sets of flow restrictors, and for small orbit radii, dynamic pressures in the discharge groove have peak values similar to those in the squeeze film land. The identified parameters include the test system damping and the individual contributions from the squeeze film, dry friction in the mechanical seal and structure remnant damping. The identified system damping coefficients are frequency and motion amplitude dependent due to the dry-friction interaction at the mechanical seal interface. Squeeze film force coefficients, damping and added mass, are in agreement with simple predictive formulas for an uncavitated lubricant condition and are similar for both flow restrictor sizes. The SFD-mechanical seal arrangement effectively prevents air ingestion and entrapment and generates predicable force coefficients for the range of frequencies tested.
    keyword(s): Force , Flow (Dynamics) , Motion , Lubricants , Dampers , Damping , Inertia (Mechanics) , Dry-friction whip and whirl , Measurement , Pressure , Stress AND Gates (Closures) ,
    • Download: (1.007Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Squeeze Film Damper With a Mechanical End Seal: Experimental Force Coefficients Derived From Circular Centered Orbits

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/137906
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorLuis San Andrés
    contributor authorAdolfo Delgado
    date accessioned2017-05-09T00:27:52Z
    date available2017-05-09T00:27:52Z
    date copyrightJuly, 2008
    date issued2008
    identifier issn1528-8919
    identifier otherJETPEZ-27026#042505_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/137906
    description abstractThe paper presents parameter identification measurements conducted on a squeeze film damper (SFD) featuring a nonrotating mechanical seal that effectively eliminates lubricant side leakage. The SFD-seal arrangement generates dissipative forces due to viscous and dry-friction effects from the lubricant film and surfaces in contact, respectively. The test damper reproduces an aircraft application that must contain the lubricant for extended periods of time. The test damper journal is 2.54cm in length and 12.7cm in diameter, with a nominal clearance of 0.127mm. The damper feed end opens to a plenum filled with lubricant, and at its discharge grooved section, four orifice ports evacuate the lubricant. In earlier publications, single frequency force excitation tests were conducted, without and with lubricant in the squeeze film land, to determine the seal dry-friction force and viscous damping force coefficients. Presently, further measurements are conducted to identify the test system and SFD force coefficients using two sets of flow restrictor orifice sizes (2.8mm and 1.1mm in diameter). The flow restrictors regulate the discharge flow area and thus control the oil flow through the squeeze film. The experiments also include measurements of dynamic pressures at the squeeze film land and at the discharge groove. The magnitude of dynamic pressure in the squeeze film land is nearly identical for both sets of flow restrictors, and for small orbit radii, dynamic pressures in the discharge groove have peak values similar to those in the squeeze film land. The identified parameters include the test system damping and the individual contributions from the squeeze film, dry friction in the mechanical seal and structure remnant damping. The identified system damping coefficients are frequency and motion amplitude dependent due to the dry-friction interaction at the mechanical seal interface. Squeeze film force coefficients, damping and added mass, are in agreement with simple predictive formulas for an uncavitated lubricant condition and are similar for both flow restrictor sizes. The SFD-mechanical seal arrangement effectively prevents air ingestion and entrapment and generates predicable force coefficients for the range of frequencies tested.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleSqueeze Film Damper With a Mechanical End Seal: Experimental Force Coefficients Derived From Circular Centered Orbits
    typeJournal Paper
    journal volume130
    journal issue4
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.2800345
    journal fristpage42505
    identifier eissn0742-4795
    keywordsForce
    keywordsFlow (Dynamics)
    keywordsMotion
    keywordsLubricants
    keywordsDampers
    keywordsDamping
    keywordsInertia (Mechanics)
    keywordsDry-friction whip and whirl
    keywordsMeasurement
    keywordsPressure
    keywordsStress AND Gates (Closures)
    treeJournal of Engineering for Gas Turbines and Power:;2008:;volume( 130 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian