description abstractThe first functional load-carrying and energetically autonomous exoskeleton was demonstrated at the University of California, Berkeley, walking at the average speed of 1.3m∕s(2.9mph) while carrying a 34kg(75lb) payload. Four fundamental technologies associated with the Berkeley lower extremity exoskeleton were tackled during the course of this project. These four core technologies include the design of the exoskeleton architecture, control schemes, a body local area network to host the control algorithm, and a series of on-board power units to power the actuators, sensors, and the computers. This paper gives an overview of one of the control schemes. The analysis here is an extension of the classical definition of the sensitivity function of a system: the ability of a system to reject disturbances or the measure of system robustness. The control algorithm developed here increases the closed-loop system sensitivity to its wearer’s forces and torques without any measurement from the wearer (such as force, position, or electromyogram signal). The control method has little robustness to parameter variations and therefore requires a relatively good dynamic model of the system. The trade-offs between having sensors to measure human variables and the lack of robustness to parameter variation are described.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Berkeley Lower Extremity Exoskeleton
typeJournal Paper
journal volume128
journal issue1
journal titleJournal of Dynamic Systems, Measurement, and Control
identifier doi10.1115/1.2168164
journal fristpage14
journal lastpage25
identifier eissn1528-9028
keywordsDynamics (Mechanics)
keywordsForce
keywordsControl equipment
keywordsMotion
keywordsDegrees of freedom
keywordsActuators
keywordsDesign
keywordsFeedback
keywordsSensors
keywordsStress
keywordsRobustness
keywordsKnee AND Dynamic models
treeJournal of Dynamic Systems, Measurement, and Control:;2006:;volume( 128 ):;issue: 001