    Inlet Fogging of Gas Turbine Engines Detailed Climatic Analysis of Gas Turbine Evaporation Cooling Potential in the USA

    Source: Journal of Engineering for Gas Turbines and Power:;2003:;volume( 125 ):;issue: 001::page 300
    Author:
    M. Chaker
    ,
    C. B. Meher-Homji
    ,
    T. Mee
    ,
    A. Nicholson
    DOI: 10.1115/1.1519266
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Inlet fogging of gas turbine engines has attained considerable popularity due to the ease of installation and the relatively low first cost compared to other inlet cooling methods. With increasing demand for power and with shortage envisioned especially during the peak load times during the summers, there is a need to boost gas turbine power. There is a sizable evaporative cooling potential throughout the world when the climatic data is evaluated based on an analysis of coincident wet bulb and dry bulk information. These data are not readily available to plant users. In this paper, a detailed climatic analysis is made of 122 locations in the U.S. to provide the hours of cooling that can be obtained by direct evaporative cooling. These data will allow gas turbine operators to easily make an assessment of the economics of evaporative cooling. The paper also covers an introduction to direct evaporative cooling and the methodology and data analysis used to derive the cooling potential in different regions of the U.S. Simulation runs have been made for gas turbine simple cycles using a reference plant based on a GE Frame 7111EA gas turbine at the 122 locations studied in the U.S. to provide a feel for the sensitivity of operation with inlet fogging.
    keyword(s): Cooling , Evaporative cooling , Gas turbines AND Temperature ,
    • Download: (742.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Inlet Fogging of Gas Turbine Engines Detailed Climatic Analysis of Gas Turbine Evaporation Cooling Potential in the USA

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/128444
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorM. Chaker
    contributor authorC. B. Meher-Homji
    contributor authorT. Mee
    contributor authorA. Nicholson
    date accessioned2017-05-09T00:10:18Z
    date available2017-05-09T00:10:18Z
    date copyrightJanuary, 2003
    date issued2003
    identifier issn1528-8919
    identifier otherJETPEZ-26819#300_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/128444
    description abstractInlet fogging of gas turbine engines has attained considerable popularity due to the ease of installation and the relatively low first cost compared to other inlet cooling methods. With increasing demand for power and with shortage envisioned especially during the peak load times during the summers, there is a need to boost gas turbine power. There is a sizable evaporative cooling potential throughout the world when the climatic data is evaluated based on an analysis of coincident wet bulb and dry bulk information. These data are not readily available to plant users. In this paper, a detailed climatic analysis is made of 122 locations in the U.S. to provide the hours of cooling that can be obtained by direct evaporative cooling. These data will allow gas turbine operators to easily make an assessment of the economics of evaporative cooling. The paper also covers an introduction to direct evaporative cooling and the methodology and data analysis used to derive the cooling potential in different regions of the U.S. Simulation runs have been made for gas turbine simple cycles using a reference plant based on a GE Frame 7111EA gas turbine at the 122 locations studied in the U.S. to provide a feel for the sensitivity of operation with inlet fogging.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleInlet Fogging of Gas Turbine Engines Detailed Climatic Analysis of Gas Turbine Evaporation Cooling Potential in the USA
    typeJournal Paper
    journal volume125
    journal issue1
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.1519266
    journal fristpage300
    journal lastpage309
    identifier eissn0742-4795
    keywordsCooling
    keywordsEvaporative cooling
    keywordsGas turbines AND Temperature
    treeJournal of Engineering for Gas Turbines and Power:;2003:;volume( 125 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian