contributor author | K. Mathioudakis | |
contributor author | E. Bonataki | |
contributor author | A. Stamatis | |
contributor author | Senior Research Associate | |
date accessioned | 2017-05-09T00:07:28Z | |
date available | 2017-05-09T00:07:28Z | |
date copyright | April, 2002 | |
date issued | 2002 | |
identifier issn | 1528-8919 | |
identifier other | JETPEZ-26812#256_1.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/126772 | |
description abstract | A method for defining which parts of a combined cycle gas turbine (CCGT) power plant are responsible for performance deviations is presented. When the overall performances deviate from their baseline values, application of the method allows the determination of the component(s) of the plant, responsible for this deviation. It is shown that simple differentiation approaches may lead to erroneous conclusions, because they do not reveal the nature of deviations for individual components. Contributions of individual components are then assessed by separating deviations due to permanent changes and deviations due to change of operating conditions. A generalized formulation is presented together with the way of implementing it. Test cases are given, to make clearer the ideas put forward in the proposed method. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Allocating the Causes of Performance Deterioration in Combined Cycle Gas Turbine Plants | |
type | Journal Paper | |
journal volume | 124 | |
journal issue | 2 | |
journal title | Journal of Engineering for Gas Turbines and Power | |
identifier doi | 10.1115/1.1426407 | |
journal fristpage | 256 | |
journal lastpage | 262 | |
identifier eissn | 0742-4795 | |
keywords | Gas turbines | |
keywords | Cycles | |
keywords | Industrial plants | |
keywords | Heat recovery steam generators AND Thermal power stations | |
tree | Journal of Engineering for Gas Turbines and Power:;2002:;volume( 124 ):;issue: 002 | |
contenttype | Fulltext | |