Comparative Measurements of Different Solar Flux Gauge TypesSource: Journal of Solar Energy Engineering:;2001:;volume( 123 ):;issue: 003::page 251DOI: 10.1115/1.1385201Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: At the DLR Solar Furnace, calorimeters or circular foil radiometers are used for calibrating video camera based flux mapping systems. For many years, we have been investigating the accuracy of these devices and have undertaken several efforts to check their performance. Furthermore, we developed new instruments and compared these devices to the existent ones. The most recent measurements were collected within the frame of an international campaign, called Intercomp 2000, located at the DLR Solar Furnace in Cologne. This was the opportunity to test our own flux gauges, the 10000 suns Kendall radiometer, the 5000 suns SunCatch calorimeter, 2 HyCal circular foil radiometers for 3000 suns and 2 more HyCal radiometers for 11000 suns. About 100 measurements were taken in the range from 0,5 MW/m2 up to 5 MW/m2. The Kendall radiometer and the SunCatch calorimeter agreed well within the 2% margin. The circular foil HyCal radiometers showed significantly larger deviations. This leads to the conclusion that we have to change the manufacturer-given calibration constants of the HyCal radiometers by using the data collected with either the SunCatch or the Kendall flux gauge.
keyword(s): Measurement , Gages , Instrumentation , Solar energy , Calibration AND Furnaces ,
|
Collections
Show full item record
contributor author | Jens Kaluza | |
contributor author | Andreas Neumann | |
date accessioned | 2017-05-09T00:05:54Z | |
date available | 2017-05-09T00:05:54Z | |
date copyright | August, 2001 | |
date issued | 2001 | |
identifier issn | 0199-6231 | |
identifier other | JSEEDO-28304#251_1.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/125818 | |
description abstract | At the DLR Solar Furnace, calorimeters or circular foil radiometers are used for calibrating video camera based flux mapping systems. For many years, we have been investigating the accuracy of these devices and have undertaken several efforts to check their performance. Furthermore, we developed new instruments and compared these devices to the existent ones. The most recent measurements were collected within the frame of an international campaign, called Intercomp 2000, located at the DLR Solar Furnace in Cologne. This was the opportunity to test our own flux gauges, the 10000 suns Kendall radiometer, the 5000 suns SunCatch calorimeter, 2 HyCal circular foil radiometers for 3000 suns and 2 more HyCal radiometers for 11000 suns. About 100 measurements were taken in the range from 0,5 MW/m2 up to 5 MW/m2. The Kendall radiometer and the SunCatch calorimeter agreed well within the 2% margin. The circular foil HyCal radiometers showed significantly larger deviations. This leads to the conclusion that we have to change the manufacturer-given calibration constants of the HyCal radiometers by using the data collected with either the SunCatch or the Kendall flux gauge. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Comparative Measurements of Different Solar Flux Gauge Types | |
type | Journal Paper | |
journal volume | 123 | |
journal issue | 3 | |
journal title | Journal of Solar Energy Engineering | |
identifier doi | 10.1115/1.1385201 | |
journal fristpage | 251 | |
journal lastpage | 255 | |
identifier eissn | 1528-8986 | |
keywords | Measurement | |
keywords | Gages | |
keywords | Instrumentation | |
keywords | Solar energy | |
keywords | Calibration AND Furnaces | |
tree | Journal of Solar Energy Engineering:;2001:;volume( 123 ):;issue: 003 | |
contenttype | Fulltext |