    Design and Performance Verification of a 62-MWt CFB Boiler

    Source: Journal of Engineering for Gas Turbines and Power:;2001:;volume( 123 ):;issue: 001::page 240
    Author:
    K. Cen
    ,
    P. Basu
    ,
    L. Cheng
    ,
    M.-X. Fang
    ,
    Z.-Y. Luo
    DOI: 10.1115/1.1340621
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The present paper discusses the goals and methods of design of a circulating fluidized bed (CFB) boiler: A 62-MWt (75-T/h) CFB boiler was designed manually using experience and available published data. The design was regenerated by an Expert System for evaluation and confirmation of the manual design. Design choices and resulting surface areas from these two approaches were compared and validated. Final confirmation of the design can be obtained only from operation of the boiler. The boiler was built and commissioned in the Jiangshu Province, China, firing the design coal. A comprehensive test program was undertaken to monitor the performance of the boiler. Predicted performance from both the manual design and the Expert System is compared with those measured in the boiler. A reasonable agreement between the predicted performance and measured values was obtained, which confirmed both experience-based design decision and that from the Expert System.
    keyword(s): Boilers , Coal , Design , Expert systems , Furnaces AND Heat ,
    • Download: (344.2Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Design and Performance Verification of a 62-MWt CFB Boiler

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/125263
    Collections
    • Journal of Engineering for Gas Turbines and Power

    Show full item record

    contributor authorK. Cen
    contributor authorP. Basu
    contributor authorL. Cheng
    contributor authorM.-X. Fang
    contributor authorZ.-Y. Luo
    date accessioned2017-05-09T00:04:57Z
    date available2017-05-09T00:04:57Z
    date copyrightJanuary, 2001
    date issued2001
    identifier issn1528-8919
    identifier otherJETPEZ-26802#240_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/125263
    description abstractThe present paper discusses the goals and methods of design of a circulating fluidized bed (CFB) boiler: A 62-MWt (75-T/h) CFB boiler was designed manually using experience and available published data. The design was regenerated by an Expert System for evaluation and confirmation of the manual design. Design choices and resulting surface areas from these two approaches were compared and validated. Final confirmation of the design can be obtained only from operation of the boiler. The boiler was built and commissioned in the Jiangshu Province, China, firing the design coal. A comprehensive test program was undertaken to monitor the performance of the boiler. Predicted performance from both the manual design and the Expert System is compared with those measured in the boiler. A reasonable agreement between the predicted performance and measured values was obtained, which confirmed both experience-based design decision and that from the Expert System.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleDesign and Performance Verification of a 62-MWt CFB Boiler
    typeJournal Paper
    journal volume123
    journal issue1
    journal titleJournal of Engineering for Gas Turbines and Power
    identifier doi10.1115/1.1340621
    journal fristpage240
    journal lastpage245
    identifier eissn0742-4795
    keywordsBoilers
    keywordsCoal
    keywordsDesign
    keywordsExpert systems
    keywordsFurnaces AND Heat
    treeJournal of Engineering for Gas Turbines and Power:;2001:;volume( 123 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian