Show simple item record

contributor authorKenji Kawashima
contributor authorResearch Associate
contributor authorToshiharu Kagawa
contributor authorToshinori Fujita
contributor authorResearch Associate
date accessioned2017-05-09T00:02:09Z
date available2017-05-09T00:02:09Z
date copyrightMarch, 2000
date issued2000
identifier issn0022-0434
identifier otherJDSMAA-26262#174_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/123510
description abstractIn this paper, a chamber called an “Isothermal Chamber” was developed. The isothermal chamber can almost realize isothermal condition due to larger heat transfer area and heat transfer coefficient by stuffing steel wool in it. Using this chamber, a simple method to measure flow rates of ideal gases was developed. As the process during charge or discharge is almost isothermal, instantaneous flow rates charged into or discharged from the chamber can be obtained measuring only pressure in the chamber. The steady and the unsteady flow rate of air were measured by the proposed method, and the effectiveness of the method was demonstrated. [S0022-0434(00)00301-4]
publisherThe American Society of Mechanical Engineers (ASME)
titleInstantaneous Flow Rate Measurement of Ideal Gases
typeJournal Paper
journal volume122
journal issue1
journal titleJournal of Dynamic Systems, Measurement, and Control
identifier doi10.1115/1.482439
journal fristpage174
journal lastpage178
identifier eissn1528-9028
keywordsPressure
keywordsFlow (Dynamics)
keywordsTemperature
keywordsGases AND Steel
treeJournal of Dynamic Systems, Measurement, and Control:;2000:;volume( 122 ):;issue: 001