description abstractIn this paper, a closed-form expression for intercept factor is used to carry out the optimization of parabolic trough collector geometry (rim angle and concentration ratio). It is shown that the presented closed-form expression eliminates the need for a detailed ray-trace computer code and facilitates optimization of the collector optical design parameters.
publisherThe American Society of Mechanical Engineers (ASME)
titleOptimization of Parabolic Trough Collector Design for Varying Manufacturing Tolerances Using a Closed-Form Expression for Intercept Factor
typeJournal Paper
journal volume116
journal issue3
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.2930077
journal fristpage164
journal lastpage166
identifier eissn1528-8986
keywordsManufacturing
keywordsDesign
keywordsOptimization
keywordsParabolic troughs
keywordsComputers
keywordsGeometry AND Optical design techniques
treeJournal of Solar Energy Engineering:;1994:;volume( 116 ):;issue: 003
contenttypeFulltext