Show simple item record

contributor authorDavid Ruch
contributor authorDavid E. Claridge
date accessioned2017-05-08T23:39:31Z
date available2017-05-08T23:39:31Z
date copyrightMay, 1992
date issued1992
identifier issn0199-6231
identifier otherJSEEDO-28237#77_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/110830
description abstractThis paper develops a four-parameter change-point model of energy consumption as a function of dry-bulb temperature, along with accompanying error diagnostics for the model’s parameters. The model is a generalization of the widely used three-parameter, or variable-base degree-day method. The model is applied to data from a case study grocery store, is compared to the three-parameter PRISM CO model of the store data, and is shown to provide a statistically better fit to consumption data below about 15°C. This model appears to be useful for diagnosing unexpected energy use in some buildings and should be useful for determining retrofit energy savings from monitored pre-retrofit and post-retrofit data for the class of buildings whose pre-retrofit consumption is fit by a four-parameter linear change-point model.
publisherThe American Society of Mechanical Engineers (ASME)
titleA Four-Parameter Change-Point Model for Predicting Energy Consumption in Commercial Buildings
typeJournal Paper
journal volume114
journal issue2
journal titleJournal of Solar Energy Engineering
identifier doi10.1115/1.2929993
journal fristpage77
journal lastpage83
identifier eissn1528-8986
keywordsStructures
keywordsEnergy consumption
keywordsErrors
keywordsPrisms (Optics) AND Temperature
treeJournal of Solar Energy Engineering:;1992:;volume( 114 ):;issue: 002
contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record