contributor author | T. Yamanaka | |
contributor author | M. Kinoshita | |
date accessioned | 2017-05-08T23:35:29Z | |
date available | 2017-05-08T23:35:29Z | |
date copyright | July, 1991 | |
date issued | 1991 | |
identifier issn | 1528-8919 | |
identifier other | JETPEZ-26689#406_1.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/108521 | |
description abstract | The microwave method has advantages, such as a high degree of precision and dynamic measurement capability, for measuring TDC (Top Dead Center) in an engine. However, there are marked discrepancies between the calculation from a simplified model and experiments. Especially in the indirect-injection diesel engine, the concept of this method is not generally understood and the probe design for this method has not been established. It has been experimentally clarified that these discrepancies result mainly from the structure of the main chamber in the indirect-injection diesel engine and the measuring method of the sharpness of a microwave resonance. An optimum probe design for measuring TDC is proposed. A simple laboratory engine simulator is also proposed to simplify determination of the design parameters. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Optimum Probe Design for Precise TDC Measurement Using a Microwave Technique | |
type | Journal Paper | |
journal volume | 113 | |
journal issue | 3 | |
journal title | Journal of Engineering for Gas Turbines and Power | |
identifier doi | 10.1115/1.2906245 | |
journal fristpage | 406 | |
journal lastpage | 412 | |
identifier eissn | 0742-4795 | |
keywords | Microwaves | |
keywords | Design | |
keywords | Probes | |
keywords | Diesel engines | |
keywords | Engines | |
keywords | Accuracy AND Resonance | |
tree | Journal of Engineering for Gas Turbines and Power:;1991:;volume( 113 ):;issue: 003 | |
contenttype | Fulltext | |