    An Automation of Collector Testing and Modification of ANSI/ASHRAE 93-1986 Standard

    Source: Journal of Solar Energy Engineering:;1990:;volume( 112 ):;issue: 004::page 257
    Author:
    B. J. Huang
    ,
    S. W. Hsieh
    DOI: 10.1115/1.2929932
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: The steady-state performance test of solar collectors using ANSI/ASHRAE 93-1986 Standard was revised and an automation for the testing was carried out in the present study in order that the test can be easily performed outdoors in areas with variable weather conditions. It was shown that the 95 percent settling time of the collector τ95 can be adopted as the time basis in the selection of steady-state period for the test. To make the best use of the time available for the testing, the steady-state period defined by ANSI/ASHRAE 93-1986 Standard was changed to the τ95 plus five minutes, or ten minutes, whichever is larger. To reduce scatter uncertainty in the test results, the test period for the efficiency calculation was chosen as the segment of the last five minutes in the steady-state period and a steadiness condition defined statistically was adopted. To shorten the time for each test run a PC-based expert testing system, which is completely automatic and requires no operator, was developed in the present study. Using this expert system associated with the modified ANSI/ASHRAE 93-1986 Standard, we can effectively carry out the collector test at variable weather conditions with small scatter uncertainty and can substantially shorten the duration of a test.
    keyword(s): Testing , Steady state , Electromagnetic scattering , Uncertainty , Expert systems , Solar collectors AND Testing performance ,
    • Download: (1.394Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      An Automation of Collector Testing and Modification of ANSI/ASHRAE 93-1986 Standard

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/107446
    Collections
    • Journal of Solar Energy Engineering

    Show full item record

    contributor authorB. J. Huang
    contributor authorS. W. Hsieh
    date accessioned2017-05-08T23:33:34Z
    date available2017-05-08T23:33:34Z
    date copyrightNovember, 1990
    date issued1990
    identifier issn0199-6231
    identifier otherJSEEDO-28225#257_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/107446
    description abstractThe steady-state performance test of solar collectors using ANSI/ASHRAE 93-1986 Standard was revised and an automation for the testing was carried out in the present study in order that the test can be easily performed outdoors in areas with variable weather conditions. It was shown that the 95 percent settling time of the collector τ95 can be adopted as the time basis in the selection of steady-state period for the test. To make the best use of the time available for the testing, the steady-state period defined by ANSI/ASHRAE 93-1986 Standard was changed to the τ95 plus five minutes, or ten minutes, whichever is larger. To reduce scatter uncertainty in the test results, the test period for the efficiency calculation was chosen as the segment of the last five minutes in the steady-state period and a steadiness condition defined statistically was adopted. To shorten the time for each test run a PC-based expert testing system, which is completely automatic and requires no operator, was developed in the present study. Using this expert system associated with the modified ANSI/ASHRAE 93-1986 Standard, we can effectively carry out the collector test at variable weather conditions with small scatter uncertainty and can substantially shorten the duration of a test.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleAn Automation of Collector Testing and Modification of ANSI/ASHRAE 93-1986 Standard
    typeJournal Paper
    journal volume112
    journal issue4
    journal titleJournal of Solar Energy Engineering
    identifier doi10.1115/1.2929932
    journal fristpage257
    journal lastpage267
    identifier eissn1528-8986
    keywordsTesting
    keywordsSteady state
    keywordsElectromagnetic scattering
    keywordsUncertainty
    keywordsExpert systems
    keywordsSolar collectors AND Testing performance
    treeJournal of Solar Energy Engineering:;1990:;volume( 112 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian