contributor author | C. M. Grondahl | |
contributor author | R. D. Linnell | |
contributor author | T. J. Martin | |
date accessioned | 2017-05-08T23:29:51Z | |
date available | 2017-05-08T23:29:51Z | |
date copyright | October, 1989 | |
date issued | 1989 | |
identifier issn | 1528-8919 | |
identifier other | JETPEZ-26672#631_1.pdf | |
identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/105335 | |
description abstract | Application of the GE MS5001 gas turbine performance improvement uprate package has been extended to an early model “K” unit at Texaco’s Convent, LA, refinery. This extensive modification required replacement of the turbine shell in addition to the installation of new technology components developed for more recent MS5001 models. This paper presents the customer’s motivation to refurbish a 22-year-old gas turbine. Gas turbine component design improvements and interfaces are discussed with performance and reliability gains. Field service engineering experience installing the uprate is also related. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | The Modernization of a 1965 MS5001 Gas Turbine: New Life for an Old Unit | |
type | Journal Paper | |
journal volume | 111 | |
journal issue | 4 | |
journal title | Journal of Engineering for Gas Turbines and Power | |
identifier doi | 10.1115/1.3240303 | |
journal fristpage | 631 | |
journal lastpage | 636 | |
identifier eissn | 0742-4795 | |
keywords | Gas turbines | |
keywords | Turbines | |
keywords | Shells | |
keywords | Reliability AND Design | |
tree | Journal of Engineering for Gas Turbines and Power:;1989:;volume( 111 ):;issue: 004 | |
contenttype | Fulltext | |