    Heat Pump Ground Coil Analysis With Thermal Interference

    Source: Journal of Solar Energy Engineering:;1988:;volume( 110 ):;issue: 002::page 67
    Author:
    V. C. Mei
    DOI: 10.1115/1.3268247
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: When two horizontal ground coils are buried in the same trench, one on top of the other, the total energy exchange between coils and ground increases drastically over that of a single coil for the same trench length. However, because of the thermal interference between the two coils, the overall performance of the two-coil trench is very difficult to determine. Traditionally this type of problem is handled by the line source mirror-image approach. However, in applying the line source approach, the strength of the source is not known precisely and must be estimated. Most designers will estimate this value very conservatively in order to be on the safe side, and this will result in a longer coil than is actually needed. This paper provides a detailed mathematical model to describe the operation of the two-coil system that can calculate more realistically the performance of the ground coils, which in turn could make the ground coil heat pump system more economically competitive with other heating and cooling systems. The effect of thermal interference is clearly shown in the calculated soil temperature profile. The effect of fluid inlet positions, from upper or lower coils, is also studied. The comparison of measured and calculated daily energy absorbed from the ground indicated a maximum error of 27 percent, with the average error at less than 12 percent, calculated values are on the conservative side. This model is better than the line source approach for calculating the performance of two coils in the same trench. It can be used for design purposes, or used to check such coil designs by other methods.
    keyword(s): Heat pumps , Errors , Fluids , Design , Heating and cooling , Mirrors , Soil AND Temperature profiles ,
    • Download: (535.8Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Heat Pump Ground Coil Analysis With Thermal Interference

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/104435
    Collections
    • Journal of Solar Energy Engineering

    Show full item record

    contributor authorV. C. Mei
    date accessioned2017-05-08T23:28:12Z
    date available2017-05-08T23:28:12Z
    date copyrightMay, 1988
    date issued1988
    identifier issn0199-6231
    identifier otherJSEEDO-28205#67_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/104435
    description abstractWhen two horizontal ground coils are buried in the same trench, one on top of the other, the total energy exchange between coils and ground increases drastically over that of a single coil for the same trench length. However, because of the thermal interference between the two coils, the overall performance of the two-coil trench is very difficult to determine. Traditionally this type of problem is handled by the line source mirror-image approach. However, in applying the line source approach, the strength of the source is not known precisely and must be estimated. Most designers will estimate this value very conservatively in order to be on the safe side, and this will result in a longer coil than is actually needed. This paper provides a detailed mathematical model to describe the operation of the two-coil system that can calculate more realistically the performance of the ground coils, which in turn could make the ground coil heat pump system more economically competitive with other heating and cooling systems. The effect of thermal interference is clearly shown in the calculated soil temperature profile. The effect of fluid inlet positions, from upper or lower coils, is also studied. The comparison of measured and calculated daily energy absorbed from the ground indicated a maximum error of 27 percent, with the average error at less than 12 percent, calculated values are on the conservative side. This model is better than the line source approach for calculating the performance of two coils in the same trench. It can be used for design purposes, or used to check such coil designs by other methods.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleHeat Pump Ground Coil Analysis With Thermal Interference
    typeJournal Paper
    journal volume110
    journal issue2
    journal titleJournal of Solar Energy Engineering
    identifier doi10.1115/1.3268247
    journal fristpage67
    journal lastpage73
    identifier eissn1528-8986
    keywordsHeat pumps
    keywordsErrors
    keywordsFluids
    keywordsDesign
    keywordsHeating and cooling
    keywordsMirrors
    keywordsSoil AND Temperature profiles
    treeJournal of Solar Energy Engineering:;1988:;volume( 110 ):;issue: 002
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian