Show simple item record

contributor authorJ. Watton
date accessioned2017-05-08T23:24:37Z
date available2017-05-08T23:24:37Z
date copyrightMarch, 1987
date issued1987
identifier issn0022-0434
identifier otherJDSMAA-26096#19_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/102347
description abstractThe effect of a return line orifice on the steady-state performance and dynamic characteristics of a servovalve flapper/nozzle stage is investigated. Generalized design characteristics are initially developed and a specific application is then pursued by including torque motor dynamics. The possible cause of high frequency whistle within such systems is then discussed. A sufficient condition for valve whistle is established and shown to be critically dependent upon the supply pressure.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Effect of Drain Orifice Damping on the Performance Characteristics of a Servovalve Flapper/Nozzle Stage
typeJournal Paper
journal volume109
journal issue1
journal titleJournal of Dynamic Systems, Measurement, and Control
identifier doi10.1115/1.3143812
journal fristpage19
journal lastpage23
identifier eissn1528-9028
treeJournal of Dynamic Systems, Measurement, and Control:;1987:;volume( 109 ):;issue: 001
contenttypeFulltext