YaBeSH Engineering and Technology Library

    • Journals
    • PaperQuest
    • YSE Standards
    • YaBeSH
    • Login
    View Item 
    •   YE&T Library
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    •   YE&T Library
    • ASME
    • Journal of Dynamic Systems, Measurement, and Control
    • View Item
    • All Fields
    • Source Title
    • Year
    • Publisher
    • Title
    • Subject
    • Author
    • DOI
    • ISBN
    Advanced Search
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Archive

    Application of the Monte Carlo Method for Capacitive Pressure Transmitters Surveillance in Nuclear Power Plants

    Source: Journal of Dynamic Systems, Measurement, and Control:;2012:;volume( 134 ):;issue: 003::page 31014
    Author:
    C. Montalvo
    ,
    J. Blázquez
    ,
    M. Balbás
    ,
    A. García-Berrocal
    DOI: 10.1115/1.4005509
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: In nuclear power plants (NPPs), according to current regulations, the response time of capacitive pressure transmitters is used as an index for surveillance. Such measurement can be carried out in situ applying the noise analysis techniques to the sensor output signal. The method is well established, and it is based on the autoregressive (AR) fitting optimized by the Akaike criterion (AIC). The sensor response is influenced by the sensing line, and its length is different in each plant. Recent empirical research has proved that the sensor inner structure can be modeled with a two real poles transfer function. In the present work, it has been proved that the noise analysis applied to the simulated response of a transmitter, modeled with two poles coupled with a sensing line, gives erroneous values for the ramp time delay when the sensing line is long. Specifically, the order of the AR model supplied by the Akaike criterion is not appropriate. Therefore, a Monte Carlo method is proposed to be applied in order to establish a new criterion, based on the statistical analysis of the repeatability of the ramp time delay obtained with the AR model.
    keyword(s): Poles (Building) , Pressure sensors , Noise (Sound) , Delays , Monte Carlo methods , Nuclear power stations , Signals , Surveillance , Sensors , Simulation , Industrial plants AND Transfer functions ,
    • Download: (910.6Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Statistics

      Application of the Monte Carlo Method for Capacitive Pressure Transmitters Surveillance in Nuclear Power Plants

    URI
    https://yetl.yabesh.ir/yetl1/handle/yetl/148496
    Collections
    • Journal of Dynamic Systems, Measurement, and Control

    Show full item record

    contributor authorC. Montalvo
    contributor authorJ. Blázquez
    contributor authorM. Balbás
    contributor authorA. García-Berrocal
    date accessioned2017-05-09T00:49:11Z
    date available2017-05-09T00:49:11Z
    date copyrightMay, 2012
    date issued2012
    identifier issn0022-0434
    identifier otherJDSMAA-26586#031014_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/148496
    description abstractIn nuclear power plants (NPPs), according to current regulations, the response time of capacitive pressure transmitters is used as an index for surveillance. Such measurement can be carried out in situ applying the noise analysis techniques to the sensor output signal. The method is well established, and it is based on the autoregressive (AR) fitting optimized by the Akaike criterion (AIC). The sensor response is influenced by the sensing line, and its length is different in each plant. Recent empirical research has proved that the sensor inner structure can be modeled with a two real poles transfer function. In the present work, it has been proved that the noise analysis applied to the simulated response of a transmitter, modeled with two poles coupled with a sensing line, gives erroneous values for the ramp time delay when the sensing line is long. Specifically, the order of the AR model supplied by the Akaike criterion is not appropriate. Therefore, a Monte Carlo method is proposed to be applied in order to establish a new criterion, based on the statistical analysis of the repeatability of the ramp time delay obtained with the AR model.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleApplication of the Monte Carlo Method for Capacitive Pressure Transmitters Surveillance in Nuclear Power Plants
    typeJournal Paper
    journal volume134
    journal issue3
    journal titleJournal of Dynamic Systems, Measurement, and Control
    identifier doi10.1115/1.4005509
    journal fristpage31014
    identifier eissn1528-9028
    keywordsPoles (Building)
    keywordsPressure sensors
    keywordsNoise (Sound)
    keywordsDelays
    keywordsMonte Carlo methods
    keywordsNuclear power stations
    keywordsSignals
    keywordsSurveillance
    keywordsSensors
    keywordsSimulation
    keywordsIndustrial plants AND Transfer functions
    treeJournal of Dynamic Systems, Measurement, and Control:;2012:;volume( 134 ):;issue: 003
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian