    Thermodynamic Performance Assessment of Air Conditioner Combining Evaporative and Passive Cooling

    Thumbnail
    View/Open
    tsea_16_5_051003.pdf (854.1Kb)
    Date
    2024
    Author
    Gupta, Sunil Kumar
    Arora, B. B.
    Arora, Akhilesh
    Metadata
    Show full item record
    Abstract
    The global increase in refrigeration and air conditioning applications poses a severe problem as regards the environmental degradation caused by greenhouse gas emissions. This study introduces a novel approach wherein both evaporative cooling and passive cooling are integrated to unveil notable enhancements in energy and exergy compared to conventional air conditioning systems. Therefore, this work aims to enhance the thermal performance of a 1.5-ton split air conditioner (SAC) employing outdoor (condenser) evaporative and indoor passive cooling (EPC). The heat removal capacity of a condenser and SAC performance are greatly affected by the air temperature at the condenser inlet. Evaporative cooling serves to lower outdoor air temperature, while passive cooling minimizes the indoor cooling load. Design parameters encompass outdoor temperature (Ta = 30–44 °C), relative humidity (RH = 20–80%), and temperature reduction due to passive cooling (ΔTR = 0.5–5 °C). A model is developed to calculate the temperature reductions of outdoor air through evaporative cooling in diverse climatic conditions, while the range of passive cooling degrees is obtained from previous experiments. Results indicate a substantial enhancement in the thermodynamic performance of the proposed system. The maximum coefficient of performance (COP) improvement of 68.66% is achieved at 44 °C outside temperature and 20% relative humidity. Annual energy savings, under extreme operating conditions, range from 358.4 kWh to 2116.8 kWh. The EPC SAC is identified as more sustainable than the conventional split air conditioner (CSAC). Moreover, the projected system is anticipated to recoup its costs within a relatively short period of 1.42 years.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4302574
    Collections
    • Journal of Thermal Science and Engineering Applications

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV