Show simple item record

dc.contributor.authorGupta, Sunil Kumar
dc.contributor.authorArora, B. B.
dc.contributor.authorArora, Akhilesh
dc.date.accessioned2024-12-24T18:41:42Z
dc.date.available2024-12-24T18:41:42Z
dc.date.copyright3/12/2024 12:00:00 AM
dc.date.issued2024
dc.identifier.issn1948-5085
dc.identifier.othertsea_16_5_051003.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4302574
dc.description.abstractThe global increase in refrigeration and air conditioning applications poses a severe problem as regards the environmental degradation caused by greenhouse gas emissions. This study introduces a novel approach wherein both evaporative cooling and passive cooling are integrated to unveil notable enhancements in energy and exergy compared to conventional air conditioning systems. Therefore, this work aims to enhance the thermal performance of a 1.5-ton split air conditioner (SAC) employing outdoor (condenser) evaporative and indoor passive cooling (EPC). The heat removal capacity of a condenser and SAC performance are greatly affected by the air temperature at the condenser inlet. Evaporative cooling serves to lower outdoor air temperature, while passive cooling minimizes the indoor cooling load. Design parameters encompass outdoor temperature (Ta = 30–44 °C), relative humidity (RH = 20–80%), and temperature reduction due to passive cooling (ΔTR = 0.5–5 °C). A model is developed to calculate the temperature reductions of outdoor air through evaporative cooling in diverse climatic conditions, while the range of passive cooling degrees is obtained from previous experiments. Results indicate a substantial enhancement in the thermodynamic performance of the proposed system. The maximum coefficient of performance (COP) improvement of 68.66% is achieved at 44 °C outside temperature and 20% relative humidity. Annual energy savings, under extreme operating conditions, range from 358.4 kWh to 2116.8 kWh. The EPC SAC is identified as more sustainable than the conventional split air conditioner (CSAC). Moreover, the projected system is anticipated to recoup its costs within a relatively short period of 1.42 years.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThermodynamic Performance Assessment of Air Conditioner Combining Evaporative and Passive Cooling
dc.typeJournal Paper
dc.journal.volume16
dc.journal.issue5
dc.journal.titleJournal of Thermal Science and Engineering Applications
dc.identifier.doi10.1115/1.4064743
dc.journal.fristpage51003-1
dc.journal.lastpage51003-12
dc.page12
dc.treeJournal of Thermal Science and Engineering Applications:;2024:;volume( 016 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record