• Login
    View Item 
    •   DSpace Home
    • ASME
    • Journal of Solar Energy Engineering
    • View Item
    •   DSpace Home
    • ASME
    • Journal of Solar Energy Engineering
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Three-Dimensional Thermo-Hydraulic Analysis of Solar Air Heater With Equilateral Prism-Shaped Rib Roughness

    Thumbnail
    View/Open
    sol_142_5_051001.pdf (2.549Mb)
    Date
    2020
    Author
    Ahmad, Inzamam
    Khan, N. H.
    Hassan, M. A.
    Paswan, M. K.
    Metadata
    Show full item record
    Abstract
    Thermal transport and flow friction characteristics due to roughness on the absorber plate of solar air heater are evaluated by applying three-dimensional finite volume based code. Renormalization group (RNG) k–ɛ model is employed to capture the turbulent nature of the flow. The effect of equilateral prism-shaped rib roughness geometrical parameters in terms of relative roughness height (e/D) and relative roughness pitch (p/e) on heat transfer and flow friction is analyzed. Further, the effect of flow parameter, Re in the range of 4000–18,000 is also explored. Results are elucidated in terms of average Nusselt number, friction factor, turbulent kinetic energy, and eddy dissipation. Results are compared with a smooth absorber plate solar air heater. Thermo-hydraulic performance of the roughened solar air heater is analyzed. Noteworthy augmentation in heat transport is obtained. The thermal enhancement factor is calculated for optimal performance and found to vary from 1.7 to 3.5. However, friction factor and pressure loss for roughened plate is significantly higher than its smooth counterpart. The pressure drop across the test section increases with the rise in roughness height due to flow obstruction. A minimum value of the friction factor enhancement ratio worth 2.13 is obtained. Enhancement in thermal transport and pressure losses are combined by introducing a thermo-hydraulic performance factor (THHP). For the range of parameters investigated, the optimum value of the thermo-hydraulic performance factor is found to be 3.41. Correlations for average Nusselt number and friction factor are offered at the end.
    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/4274317
    Collections
    • Journal of Solar Energy Engineering

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    Statistics

    View Usage Statistics

    DSpace software copyright © 2002-2015  DuraSpace
    Contact Us | Send Feedback
    Theme by 
    @mire NV