Show simple item record

dc.contributor.authorAhmad, Inzamam
dc.contributor.authorKhan, N. H.
dc.contributor.authorHassan, M. A.
dc.contributor.authorPaswan, M. K.
dc.date.accessioned2022-02-04T14:45:40Z
dc.date.available2022-02-04T14:45:40Z
dc.date.copyright2020/02/07/
dc.date.issued2020
dc.identifier.issn0199-6231
dc.identifier.othersol_142_5_051001.pdf
dc.identifier.urihttp://yetl.yabesh.ir/yetl1/handle/yetl/4274317
dc.description.abstractThermal transport and flow friction characteristics due to roughness on the absorber plate of solar air heater are evaluated by applying three-dimensional finite volume based code. Renormalization group (RNG) k–ɛ model is employed to capture the turbulent nature of the flow. The effect of equilateral prism-shaped rib roughness geometrical parameters in terms of relative roughness height (e/D) and relative roughness pitch (p/e) on heat transfer and flow friction is analyzed. Further, the effect of flow parameter, Re in the range of 4000–18,000 is also explored. Results are elucidated in terms of average Nusselt number, friction factor, turbulent kinetic energy, and eddy dissipation. Results are compared with a smooth absorber plate solar air heater. Thermo-hydraulic performance of the roughened solar air heater is analyzed. Noteworthy augmentation in heat transport is obtained. The thermal enhancement factor is calculated for optimal performance and found to vary from 1.7 to 3.5. However, friction factor and pressure loss for roughened plate is significantly higher than its smooth counterpart. The pressure drop across the test section increases with the rise in roughness height due to flow obstruction. A minimum value of the friction factor enhancement ratio worth 2.13 is obtained. Enhancement in thermal transport and pressure losses are combined by introducing a thermo-hydraulic performance factor (THHP). For the range of parameters investigated, the optimum value of the thermo-hydraulic performance factor is found to be 3.41. Correlations for average Nusselt number and friction factor are offered at the end.
dc.publisherThe American Society of Mechanical Engineers (ASME)
dc.titleThree-Dimensional Thermo-Hydraulic Analysis of Solar Air Heater With Equilateral Prism-Shaped Rib Roughness
dc.typeJournal Paper
dc.journal.volume142
dc.journal.issue5
dc.journal.titleJournal of Solar Energy Engineering
dc.identifier.doi10.1115/1.4046088
dc.page51001
dc.treeJournal of Solar Energy Engineering:;2020:;volume( 142 ):;issue: 005
dc.contenttypeFulltext


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record