Journal of Composites for Construction: Recent submissions
Now showing items 1841-1860 of 2137
-
Underwater Fiber–Reinforced Polymers Repair of Prestressed Piles in the Allen Creek Bridge
(American Society of Civil Engineers, 2005)This paper presents an overview of a demonstration project in which corroding prestressed piles located in tidal waters were wrapped underwater using carbon and glass fiber-reinforced polymer material. An innovative ... -
Development of the Nonlinear Bond Stress–Slip Model of Fiber Reinforced Plastics Sheet–Concrete Interfaces with a Simple Method
(American Society of Civil Engineers, 2005)A new analytical method for defining the nonlinear bond stress–slip models of fiber reinforced plastics (FRP) sheet–concrete interfaces through pullout bond test is proposed. With this method, it is not necessary to attach ... -
Rectangular Filament-Wound Glass Fiber Reinforced Polymer Tubes Filled with Concrete under Flexural and Axial Loading: Analytical Modeling
(American Society of Civil Engineers, 2005)This paper presents an analytical model to predict the behavior of concrete-filled rectangular fiber reinforced polymer (FRP) tubes (CFRFTs), subjected to bending and axial loads. The model accounts for different laminate ... -
Creep Deformation of Fiber Reinforced Plastics-Plated Reinforced Concrete Tensile Members
(American Society of Civil Engineers, 2005)The problem of long-term creep deformation of reinforced concrete tensile elements strengthened by external fiber reinforced plastic (FRP) plates is studied. Formation of discrete cracks in concrete under tension is taken ... -
Behavior of Gravity Load-Designed Rectangular Concrete Columns Confined with Fiber Reinforced Polymer Sheets
(American Society of Civil Engineers, 2005)This study concentrates on analytical evaluation of the effect of external confinement using fiber reinforced polymers (FRP) sheets on the response of concrete rectangular columns designed for gravity load only and having ... -
Rectangular Filament-Wound Glass Fiber Reinforced Polymer Tubes Filled with Concrete under Flexural and Axial Loading: Experimental Investigation
(American Society of Civil Engineers, 2005)This paper presents results of an experimental investigation on three beams and five short columns, consisting of glass fiber reinforced polymer concrete-filled rectangular filament-wound tubes (CFRFTs). The tubes included ... -
Effect of Fiber-Reinforced Polymer Confinement on Bond Strength of Reinforcement in Beam Anchorage Specimens
(American Society of Civil Engineers, 2005)This paper reports on the fourth phase of a multiphase study undertaken at the American University of Beirut (AUB) to examine the effect of fiber-reinforced polymer (FRP) sheets in confining bond-critical regions in ... -
Masonry Wall Crack Control with Carbon Fiber Reinforced Polymer
(American Society of Civil Engineers, 2005)Restrained shrinkage is a major source of damage to buildings. By the combination of different construction materials, or through different conditions of exposure of different structural elements, differential dimensional ... -
Behavior of Composite Unreinforced Masonry–Fiber-Reinforced Polymer Wall Assemblages Under In-Plane Loading
(American Society of Civil Engineers, 2005)An experimental investigation was conducted to study the in-plane behavior of face shell mortar bedded unreinforced masonry (URM) wall assemblages retrofitted with fiber-reinforced polymer (FRP) laminates. Forty-two URM ... -
Experimental Study of a Bonded Plastic Fiber Reinforced Polymer Connector Assembly
(American Society of Civil Engineers, 2004)In this paper the physical behaviors of a connection assembly comprising a molded glass reinforced plastic [plastic fiber reinforced polymer (PFRP)] connector unit currently commercially manufactured from sheet molding ... -
Reviewers
(American Society of Civil Engineers, 2004) -
Ultimate Condition of Fiber Reinforced Polymer-Confined Concrete
(American Society of Civil Engineers, 2004)One important application of fiber reinforced polymer (FRP) composites is as a confining material for concrete in the retrofit of existing concrete columns by the provision of FRP jackets. Such jackets are commonly formed ... -
Modeling the Behavior of Fiber Reinforced Polymer-Confined Concrete Columns Exposed to Fire
(American Society of Civil Engineers, 2005)Very little information is available on the behavior of fiber reinforced polymer (FRP) materials and FRP-strengthened concrete members in fire, and this is a primary factor hindering the widespread implementation of FRP ... -
Axial and Shear Behavior of Glass Fiber Reinforced Gypsum Wall Panels: Tests
(American Society of Civil Engineers, 2004)Glass fiber reinforced gypsum (GFRG) walls and their associated building system are the new building product and building system that have been developed in the Australian building industry in the last decade. GFRG walls ... -
Simple Carbon-Fiber-Reinforced-Plastic-Confined Concrete Model for Moment-Curvature Analysis
(American Society of Civil Engineers, 2005)This paper presents a simple model to calculate concrete properties for reinforced concrete members that are confined by carbon-fiber-reinforced plastic (CFRP) sheets. The model simplifies and incorporates formulas from ... -
Stay-in-Place Fiber Reinforced Polymer Forms for Precast Modular Bridge Pier System
(American Society of Civil Engineers, 2004)This paper presents an innovative modular construction of bridge pier system with stay-in-place fiber reinforced polymer (FRP) forms filled with concrete. Two 1/6 scale precast modular frames were prepared of a prototype ... -
EDITOR'S NOTE
(American Society of Civil Engineers, 2005) -
Ductile Design of Reinforced Concrete Beams Retrofitted with Fiber Reinforced Polymer Plates
(American Society of Civil Engineers, 2004)For reinforced concrete beams retrofitted with fiber-reinforced polymer (FRP) plates, an analytical method is derived for determining the allowable plate area to achieve a targeted value of ductility. Nonlinear models for ... -
Environmental Impact of Steel and Fiber–Reinforced Polymer Reinforced Pavements
(American Society of Civil Engineers, 2004)The environmental load of fiber-reinforced polymer (FRP) reinforced pavement was compared with that of steel reinforced pavement. Replacing steel rebars with FRP rebars can lead to changes in the concrete mix and pavement ... -
Bond Between Near-Surface Mounted Carbon-Fiber-Reinforced Polymer Laminate Strips and Concrete
(American Society of Civil Engineers, 2004)In recent years, a strengthening technique based on near-surface mounted (NSM) laminate strips of carbon-fiber-reinforced polymer (CFRP) has been used to increase the load-carrying capacity of concrete and masonry structures ...