    A Method for Recognizing Structural Nonlinearities in Steady-State Harmonic Testing

    Source: Journal of Vibration and Acoustics:;1984:;volume( 106 ):;issue: 001::page 49
    Author:
    J. Kirshenboim
    ,
    D. J. Ewins
    DOI: 10.1115/1.3269151
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: A method for recognizing the extent of the nonlinearity of data acquired by the steady-state harmonic excitation methods is developed. The level of the nonlinearity is defined by a single parameter—the J factor—in the range 1–0 (1 for perfect linearity). An example of the application of the J factor is given.
    keyword(s): Testing AND Steady state ,
    • Download: (313.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      A Method for Recognizing Structural Nonlinearities in Steady-State Harmonic Testing

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/99228
    Collections
    • Journal of Vibration and Acoustics

    Show full item record

    contributor authorJ. Kirshenboim
    contributor authorD. J. Ewins
    date accessioned2017-05-08T23:19:12Z
    date available2017-05-08T23:19:12Z
    date copyrightJanuary, 1984
    date issued1984
    identifier issn1048-9002
    identifier otherJVACEK-28960#49_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/99228
    description abstractA method for recognizing the extent of the nonlinearity of data acquired by the steady-state harmonic excitation methods is developed. The level of the nonlinearity is defined by a single parameter—the J factor—in the range 1–0 (1 for perfect linearity). An example of the application of the J factor is given.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleA Method for Recognizing Structural Nonlinearities in Steady-State Harmonic Testing
    typeJournal Paper
    journal volume106
    journal issue1
    journal titleJournal of Vibration and Acoustics
    identifier doi10.1115/1.3269151
    journal fristpage49
    journal lastpage52
    identifier eissn1528-8927
    keywordsTesting AND Steady state
    treeJournal of Vibration and Acoustics:;1984:;volume( 106 ):;issue: 001
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian