description abstract | The otolith organs are the linear motion sensors of the inner ear. They comprise an overdamped second-order system and respond to gravity and skull acceleration. The governing equations of motion which describe the relative displacement of the mass with respect to the skull are developed. When these equations are non-dimensionalized they indicate that the elastic term is almost negligible with respect to the viscous and inertial terms. For a step change in skull velocity an analytic solution is given for the elastic term equal to zero and numeric solutions are given for small values of the elastic term. | |
publisher | The American Society of Mechanical Engineers (ASME) | |
title | Governing Equations of Motion for the Otolith Organs and Their Response to a Step Change in Velocity of the Skull | |
type | Journal Paper | |
journal volume | 106 | |
journal issue | 4 | |
journal title | Journal of Biomechanical Engineering | |
identifier doi | 10.1115/1.3138498 | |
journal fristpage | 302 | |
journal lastpage | 308 | |
identifier eissn | 1528-8951 | |
keywords | Equations of motion | |
keywords | Ear | |
keywords | Displacement | |
keywords | Equations | |
keywords | Gravity (Force) | |
keywords | Sensors AND Motion | |
tree | Journal of Biomechanical Engineering:;1984:;volume( 106 ):;issue: 004 | |
contenttype | Fulltext | |