    The Effect of Test System Misalignment in the Dynamic Tension Test

    Source: Journal of Engineering Materials and Technology:;1982:;volume( 104 ):;issue: 004::page 285
    Author:
    Han C. Wu
    ,
    T. P. Wang
    ,
    M. C. Yip
    DOI: 10.1115/1.3225078
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: An analysis of test system misalignment is presented for dynamic tension test. Sheet type rectangular 1100-0 aluminum specimens are used for discussion. For a constant strain rate tension test, the strain rate is constant only on the neutral axis of the specimen. The lower the strain rate is, the more significant the misalignment errors become. The neutral axis will shift away from the centerline of the specimen as the plastic strain increases. But, it will reach a limit and will not completely move back to the centerline.
    keyword(s): Tension , Aluminum AND Errors ,
    • Download: (489.7Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      The Effect of Test System Misalignment in the Dynamic Tension Test

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/95866
    Collections
    • Journal of Engineering Materials and Technology

    Show full item record

    contributor authorHan C. Wu
    contributor authorT. P. Wang
    contributor authorM. C. Yip
    date accessioned2017-05-08T23:13:24Z
    date available2017-05-08T23:13:24Z
    date copyrightOctober, 1982
    date issued1982
    identifier issn0094-4289
    identifier otherJEMTA8-26889#285_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/95866
    description abstractAn analysis of test system misalignment is presented for dynamic tension test. Sheet type rectangular 1100-0 aluminum specimens are used for discussion. For a constant strain rate tension test, the strain rate is constant only on the neutral axis of the specimen. The lower the strain rate is, the more significant the misalignment errors become. The neutral axis will shift away from the centerline of the specimen as the plastic strain increases. But, it will reach a limit and will not completely move back to the centerline.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleThe Effect of Test System Misalignment in the Dynamic Tension Test
    typeJournal Paper
    journal volume104
    journal issue4
    journal titleJournal of Engineering Materials and Technology
    identifier doi10.1115/1.3225078
    journal fristpage285
    journal lastpage290
    identifier eissn1528-8889
    keywordsTension
    keywordsAluminum AND Errors
    treeJournal of Engineering Materials and Technology:;1982:;volume( 104 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian