| contributor author | R. D. Crowninshield | |
| contributor author | D. R. Pedersen | |
| contributor author | R. A. Brand | |
| date accessioned | 2017-05-08T23:08:13Z | |
| date available | 2017-05-08T23:08:13Z | |
| date copyright | August, 1980 | |
| date issued | 1980 | |
| identifier issn | 0148-0731 | |
| identifier other | JBENDY-25658#230_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/93021 | |
| description abstract | Strain measurement was performed on loaded fresh human cadaveric proximal femurs before and after total hip femoral component implantation. Changes in the femurs’ strain state associated with loading through stainless steel and titanium femoral components were recorded. The role of proximal femur remodeling in femoral component loosening is discussed along with the likely effect of femoral component elastic modulus on the remodeling process. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | A Measurement of Proximal Femur Strain with Total Hip Arthroplasty | |
| type | Journal Paper | |
| journal volume | 102 | |
| journal issue | 3 | |
| journal title | Journal of Biomechanical Engineering | |
| identifier doi | 10.1115/1.3149578 | |
| journal fristpage | 230 | |
| journal lastpage | 233 | |
| identifier eissn | 1528-8951 | |
| keywords | Elastic moduli | |
| keywords | Stainless steel | |
| keywords | Strain measurement | |
| keywords | Titanium AND Arthroplasty | |
| tree | Journal of Biomechanical Engineering:;1980:;volume( 102 ):;issue: 003 | |
| contenttype | Fulltext | |