    Electrogoniometer for the Measurement of Human Elbow Joint Rotation

    Source: Journal of Biomechanical Engineering:;1980:;volume( 102 ):;issue: 004::page 301
    Author:
    E. Y. Chao
    ,
    K. N. An
    ,
    L. J. Askew
    ,
    B. F. Morrey
    DOI: 10.1115/1.3138227
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: Since the electrogoniometric method has been justified for the measurement of lower extremity joint motion, a similar device is developed for the measurement of elbow joint and forearm rotations. In this design, the axis of forearm rotation coincides with the anatomical axis which eliminates the cross talk existing in the regular triaxial goniometer. Although the axis of abduction-adduction is still offset from the elbow joint, special linkage arrangement was used to obtain equivalent motion. Experimental method was used to validate the accuracy of the device and model simulation was performed to emphasize the importance of accurate placement of the instrument on test subjects. Application of the present apparatus to normal subjects was studied to illustrate the range of elbow motion required in performing normal activities of daily living. This device is currently used in the functional evaluation of patients with elbow and forearm problems.
    keyword(s): Rotation , Human elbow , Motion , Simulation , Linkages , Design AND Instrumentation ,
    • Download: (3.212Mb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Electrogoniometer for the Measurement of Human Elbow Joint Rotation

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/93005
    Collections
    • Journal of Biomechanical Engineering

    Show full item record

    contributor authorE. Y. Chao
    contributor authorK. N. An
    contributor authorL. J. Askew
    contributor authorB. F. Morrey
    date accessioned2017-05-08T23:08:11Z
    date available2017-05-08T23:08:11Z
    date copyrightNovember, 1980
    date issued1980
    identifier issn0148-0731
    identifier otherJBENDY-25663#301_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/93005
    description abstractSince the electrogoniometric method has been justified for the measurement of lower extremity joint motion, a similar device is developed for the measurement of elbow joint and forearm rotations. In this design, the axis of forearm rotation coincides with the anatomical axis which eliminates the cross talk existing in the regular triaxial goniometer. Although the axis of abduction-adduction is still offset from the elbow joint, special linkage arrangement was used to obtain equivalent motion. Experimental method was used to validate the accuracy of the device and model simulation was performed to emphasize the importance of accurate placement of the instrument on test subjects. Application of the present apparatus to normal subjects was studied to illustrate the range of elbow motion required in performing normal activities of daily living. This device is currently used in the functional evaluation of patients with elbow and forearm problems.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleElectrogoniometer for the Measurement of Human Elbow Joint Rotation
    typeJournal Paper
    journal volume102
    journal issue4
    journal titleJournal of Biomechanical Engineering
    identifier doi10.1115/1.3138227
    journal fristpage301
    journal lastpage310
    identifier eissn1528-8951
    keywordsRotation
    keywordsHuman elbow
    keywordsMotion
    keywordsSimulation
    keywordsLinkages
    keywordsDesign AND Instrumentation
    treeJournal of Biomechanical Engineering:;1980:;volume( 102 ):;issue: 004
    contenttypeFulltext