Show simple item record

contributor authorJ. C. Ziegert
contributor authorJ. L. Lewis
date accessioned2017-05-08T23:06:21Z
date available2017-05-08T23:06:21Z
date copyrightAugust, 1979
date issued1979
identifier issn0148-0731
identifier otherJBENDY-25632#218_1.pdf
identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/91910
description abstractThe effect of the soft tissue between bone and a preloaded skin surface accelerometer was studied in vivo by comparing its output with the output of an accelerometer connected directly to the bone by a needle through the soft tissue. A 34-g skin surface accelerometer gave an output with little resemblance to the bone motions, appearing to oscillate at its resonant frequency on the soft tissue. A 1.5-g skin surface accelerometer showed nearly identical output to the bone acceleration.
publisherThe American Society of Mechanical Engineers (ASME)
titleThe Effect of Soft Tissue on Measurements of Vibrational Bone Motion by Skin-Mounted Accelerometers
typeJournal Paper
journal volume101
journal issue3
journal titleJournal of Biomechanical Engineering
identifier doi10.1115/1.3426248
journal fristpage218
journal lastpage220
identifier eissn1528-8951
keywordsMeasurement
keywordsMotion
keywordsAccelerometers
keywordsBone
keywordsSkin
keywordsSoft tissues AND needles
treeJournal of Biomechanical Engineering:;1979:;volume( 101 ):;issue: 003