An Experimental Study of Surge in Centrifugal CompressorsSource: Journal of Fluids Engineering:;1977:;volume( 099 ):;issue: 001::page 115DOI: 10.1115/1.3448506Publisher: The American Society of Mechanical Engineers (ASME)
Abstract: Results of high-response measurements in a high-pressure-ratio centrifugal compressor during surge operation are presented. The interpretation of the data provides improved understanding of the flow mechanism of surge and the phenomena which apparently trigger surge. The mass flow throughout the compressor was observed to oscillate in synchronism during supposedly “stable” operation. Surge of the test compressor occurred when a flow perturbation, during “stable” operation, exceeded an apparent limit. When the instantaneous value of diffuser-inlet pressure recovery factor, Cp2*–4 , reached approximately 0.40–0.45, the diffuser inlet flow was badly deteriorated and surge occurred. However, gross separation of the diffuser inlet boundary layer was not observed before surge commencement. It is concluded that instantaneous operating states must be recognized for competent surge prediction. Further, doing so will probably require analysis of the entire compressor system including piping, vessels, flow resistances, etc.
keyword(s): Compressors , Surges , Flow (Dynamics) , Diffusers , Pressure , Boundary layers , Pipes , Separation (Technology) , Measurement , Vessels AND Mechanisms ,
|
Collections
Show full item record
| contributor author | Kosuke Toyama | |
| contributor author | P. W. Runstadler | |
| contributor author | R. C. Dean | |
| date accessioned | 2017-05-08T23:03:14Z | |
| date available | 2017-05-08T23:03:14Z | |
| date copyright | March, 1977 | |
| date issued | 1977 | |
| identifier issn | 0098-2202 | |
| identifier other | JFEGA4-26910#115_1.pdf | |
| identifier uri | http://yetl.yabesh.ir/yetl/handle/yetl/90094 | |
| description abstract | Results of high-response measurements in a high-pressure-ratio centrifugal compressor during surge operation are presented. The interpretation of the data provides improved understanding of the flow mechanism of surge and the phenomena which apparently trigger surge. The mass flow throughout the compressor was observed to oscillate in synchronism during supposedly “stable” operation. Surge of the test compressor occurred when a flow perturbation, during “stable” operation, exceeded an apparent limit. When the instantaneous value of diffuser-inlet pressure recovery factor, Cp2*–4 , reached approximately 0.40–0.45, the diffuser inlet flow was badly deteriorated and surge occurred. However, gross separation of the diffuser inlet boundary layer was not observed before surge commencement. It is concluded that instantaneous operating states must be recognized for competent surge prediction. Further, doing so will probably require analysis of the entire compressor system including piping, vessels, flow resistances, etc. | |
| publisher | The American Society of Mechanical Engineers (ASME) | |
| title | An Experimental Study of Surge in Centrifugal Compressors | |
| type | Journal Paper | |
| journal volume | 99 | |
| journal issue | 1 | |
| journal title | Journal of Fluids Engineering | |
| identifier doi | 10.1115/1.3448506 | |
| journal fristpage | 115 | |
| journal lastpage | 124 | |
| identifier eissn | 1528-901X | |
| keywords | Compressors | |
| keywords | Surges | |
| keywords | Flow (Dynamics) | |
| keywords | Diffusers | |
| keywords | Pressure | |
| keywords | Boundary layers | |
| keywords | Pipes | |
| keywords | Separation (Technology) | |
| keywords | Measurement | |
| keywords | Vessels AND Mechanisms | |
| tree | Journal of Fluids Engineering:;1977:;volume( 099 ):;issue: 001 | |
| contenttype | Fulltext |