    Shear Effects in Hot-Wire Measurements

    Source: Journal of Fluids Engineering:;1976:;volume( 098 ):;issue: 004::page 771
    Author:
    Ronald M. C. So
    DOI: 10.1115/1.3448481
    Publisher: The American Society of Mechanical Engineers (ASME)
    Abstract: When a circular cylinder is placed in a two-dimensional shear flow, a lift force is experienced by the cylinder. In the case of hot-wire measurements in the viscous sublayer, this will give rise to a displacement of the wire from its true position. The resultant measurements are found to be in error if the wire length to diameter ratio is > 300 and the shear gradient of the flow is large.
    keyword(s): Wire , Shear (Mechanics) , Measurement , Lift (Fluid dynamics) , Flow (Dynamics) , Shear flow , Circular cylinders , Cylinders , Displacement , Errors AND Gradients ,
    • Download: (310.5Kb)
    • Show Full MetaData Hide Full MetaData
    • Get RIS
    • Item Order
    • Go To Publisher
    • Price: 5000 Rial
    • Statistics

      Shear Effects in Hot-Wire Measurements

    URI
    http://yetl.yabesh.ir/yetl1/handle/yetl/88751
    Collections
    • Journal of Fluids Engineering

    Show full item record

    contributor authorRonald M. C. So
    date accessioned2017-05-08T23:00:54Z
    date available2017-05-08T23:00:54Z
    date copyrightDecember, 1976
    date issued1976
    identifier issn0098-2202
    identifier otherJFEGA4-26904#771_1.pdf
    identifier urihttp://yetl.yabesh.ir/yetl/handle/yetl/88751
    description abstractWhen a circular cylinder is placed in a two-dimensional shear flow, a lift force is experienced by the cylinder. In the case of hot-wire measurements in the viscous sublayer, this will give rise to a displacement of the wire from its true position. The resultant measurements are found to be in error if the wire length to diameter ratio is > 300 and the shear gradient of the flow is large.
    publisherThe American Society of Mechanical Engineers (ASME)
    titleShear Effects in Hot-Wire Measurements
    typeJournal Paper
    journal volume98
    journal issue4
    journal titleJournal of Fluids Engineering
    identifier doi10.1115/1.3448481
    journal fristpage771
    journal lastpage773
    identifier eissn1528-901X
    keywordsWire
    keywordsShear (Mechanics)
    keywordsMeasurement
    keywordsLift (Fluid dynamics)
    keywordsFlow (Dynamics)
    keywordsShear flow
    keywordsCircular cylinders
    keywordsCylinders
    keywordsDisplacement
    keywordsErrors AND Gradients
    treeJournal of Fluids Engineering:;1976:;volume( 098 ):;issue: 004
    contenttypeFulltext
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian
     
    DSpace software copyright © 2002-2015  DuraSpace
    نرم افزار کتابخانه دیجیتال "دی اسپیس" فارسی شده توسط یابش برای کتابخانه های ایرانی | تماس با یابش
    yabeshDSpacePersian